Technical Specifications
14-6
MOBIC T8 for Windows CE 3.0
C79000-G8976-C190-02
Mechanical conditions
Vibration
Operating
10 to 58 Hz, displacement 0.075 mm
10 cycles per axis, 1 octave/min.
(IEC 60068-2-6, test Fc)
58 to 150 Hz, acceleration 9.8 m/s
2
10 cycles per axis, 1 octave/min.
(IEC 60068-2-6, test Fc)
Shock
Operating
Acceleration 150m/s
2
, shock duration 11 ms (IEC
60068-2-27, test Ea)
Requirements from EN 61131-2
Freefall of unpacked MOBIC
T8
Fall height 1.20 m with protective cover closed
(MIL Std 810E 516.4)
Mechanical Data
Dimensions (H x W x D)
19.5 x 28.4 x 5.7 cm
Securing
Four M4 screw holes (max. torque 2 Nm, max
screw - in depth 7 mm)
Weight
approx. 1.7 kg
Class of Protection
Protective cover:
closed
open
IP65
IP 20
Marks of conformity
Marks of conformity
CE, UL, CUL, FCC Class A, FM Class I Division
II “FM”, e1 approval “e1”