xiv
ET 200L, ET 200L-SC and ET 200L-SC IM-SC Distributed I/O Device
EWA 4NEB 780 6009-02c
11-3
Connecting Insulated Thermocouples of the Same Type with External Com-
pensation, via a Resistance Thermometer Connected to the Resistance Mea-
surement Module, to Slot A of the Terminal Block (Example TB 16SC)
11-13
. .
11-4
Connecting Voltage Sensors (Example TB 16SC)
11-14
. . . . . . . . . . . . . . . . . . . .
11-5
Connecting 4-Wire Measuring Transducers (Example TB 16SC)
11-15
. . . . . . .
11-6
Connecting 2-wire measuring transducers (Example TB 16SC)
11-16
. . . . . . . .
11-7
4-Conductor Connection for Resistance Thermometers and Resistors (Exam-
ple TB 16SC)
11-17
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11-8
Response Time of the Analog Output Channels
11-25
. . . . . . . . . . . . . . . . . . . . . .
11-9
Connecting Loads/Actuators to a Current Output (Example TB 16SC)
11-26
. . .
11-10
Connecting Loads/Actuators to a Voltage Output via a 4-Wire Circuit (Example
TB 16SC)
11-27
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12-1
Front and Side Elevations of the 2 AI U Analog Electronic Module
12-2
. . . . . .
12-2
Block Diagram of the 2 AI U Analog Electronic Module
12-3
. . . . . . . . . . . . . . . .
12-3
Jump response
12-5
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12-4
Front and Side Elevations of the 2 AI HS U High Speed Analog Electronic
Module
12-8
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12-5
Block Diagram of the 2 AI HS U High-Speed Analog Electronic Module
12-9
.
12-6
Jump response
12-11
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12-7
Front and Side Elevations of the 2 AI I Analog Electronic Module
12-14
. . . . . . .
12-8
Block Diagram of the 2 AI I Analog Electronic Module
12-15
. . . . . . . . . . . . . . . . .
12-9
Jump Response
12-17
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12-10
Front and Side Elevations of the 2 AI I Analog Electronic Module
12-20
. . . . . . .
12-11
Block Diagram of the 2 AI I Analog Electronic Module
12-21
. . . . . . . . . . . . . . . . .
12-12
Jump Response
12-23
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12-13
Front and Side Elevations of the 2 AI HS I High-Speed Analog Electronic Mod-
ule (0/4–20mA, 4-Wire Measuring Transducer)
12-26
. . . . . . . . . . . . . . . . . . . . . . .
12-14
Block Diagram of the 2 AI HS I High-Speed Analog Electronic Module
(0/4–20mA, 4-Wire Measuring Transducer)
12-27
. . . . . . . . . . . . . . . . . . . . . . . . . .
12-15
Jump Response
12-29
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12-16
Front and Side Elevations of the 2 AI HS I High-Speed Analog Electronic Mod-
ule (4–20mA, 2-Wire Measuring Transducer)
12-32
. . . . . . . . . . . . . . . . . . . . . . . .
12-17
Block Diagram of the 2 AI HS I High-Speed Analog Electronic Module (4–20mA,
2-Wire Measuring Transducer)
12-33
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12-18
Jump response
12-35
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12-19
Front and Side Elevations of the 2 AI TC Analog Electronic Module
12-38
. . . . .
12-20
Block Diagram of the 2 AI TC Analog Electronic Module
12-39
. . . . . . . . . . . . . . .
12-21
Jump Response
12-41
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12-22
Front and Side Elevations of the 1 AI RTD Analog Electronic Module
12-44
. . .
12-23
Block Diagram of the 1 AI RTD Analog Electronic Module
12-45
. . . . . . . . . . . . .
12-24
Jump Response
12-47
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12-25
Front and Side Elevations of the 1 AO U Analog Electronic Module
12-50
. . . . .
12-26
Block Diagram of the 1 AO U Analog Electronic Module
12-51
. . . . . . . . . . . . . . .
12-27
Front and Side Elevations of the 1 AO I Analog Electronic Module
12-54
. . . . . .
12-28
Block Diagram of the 1 AO I Analog Electronic Module
12-55
. . . . . . . . . . . . . . . .
13-1
Front and Side Elevations of the 1COUNT40kHz Counter Module
13-2
. . . . . .
13-2
Block Diagram of the 1COUNT40kHz Counter Module
13-3
. . . . . . . . . . . . . . . .
13-3
Continuous Upward Counting
13-4
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13-4
Continuous Downward Counting
13-4
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13-5
Single-Pass Upward Counting
13-5
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13-6
Single-Pass Downward Counting
13-5
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13-7
Single-Pass Counting with Loaded Value and Gate Function
13-5
. . . . . . . . . . .
Contents
Содержание Metro 21 M216KA
Страница 18: ...xviii ET 200L ET 200L SC and ET 200L SC IM SC Distributed I O Device EWA 4NEB 780 6009 02c Contents ...
Страница 34: ...1 16 ET 200L ET 200L SC and ET 200L SC IM SC Distributed I O Device EWA 4NEB 780 6009 02c Product Overview ...
Страница 56: ...2 22 ET 200L ET 200L SC and ET 200L SC IM SC Distributed I O Device EWA 4NEB 780 6009 02c Installation ...
Страница 86: ...4 6 ET 200L ET 200L SC and ET 200L SC IM SC Distributed I O Device EWA 4NEB 780 6009 02c Commissioning ...
Страница 102: ...5 16 ET 200L ET 200L SC and ET 200L SC IM SC Distributed I O Device EWA 4NEB 780 6009 02c Diagnostics g ...
Страница 112: ...6 10 ET 200L ET 200L SC and ET 200L SC IM SC Distributed I O Device EWA 4NEB 780 6009 02c General Technical Data ...