Programming an extension
93
Step by step
Disconnect timeout after and external-
to-external transfer
With this option you can specify a period of time for dis-
connecting an external call. This option applies when at
least one external line is an analog line and the call is
transferred (Code 091) or forwarded (*11) to an external
destination by an authorized extension.
Required:
Programming mode must be activated (*95
31994).
elg
w
Enter the programming code.
ddh
...
efd
Enter the length of time for disconnecting calls (004 to
120 in 5-second cycles) where 004 = 20 seconds ...
060 = 300 seconds (default), etc.
w
Initial status for programming mode.
Code to disconnect timeout after
external-to-external transfer
This option allows you to set a code to restart the time-
out period for disconnecting an external call. This ap-
plies when at least one external line is an analog line,
and after a call has been transferred (Code 091) or for-
warded (*11) to an external destination by an authorized
extension.
Required:
Programming mode must be activated (*95
31994).
elh
w
Enter the programming code.
p
w
Enter a code for restarting the timeout, between 00 and
99 (default is 00).
w
Initial status for programming mode.
Once the call is transferred and answered at the
destination, a disconnect timer is activated (de-
fault is 5 minutes).
A 20-second warning tone is sent to both parties
before the call is disconnected. In order to con-
tinue the call without disconnecting, the destina-
tion number must enter this code (MF, default
"00") to restart the timeout.,
Содержание HiPath 1100
Страница 1: ...HiPath 1100 HiPath 1120 HiPath 1150 HiPath 1190 Analog MF Telephones Programming Manual ...
Страница 111: ...General settings 111 Step by step w Initial status for programming mode ...
Страница 199: ...Setup and Installation 199 Required Tools HiPath 1120 Package Contents ...
Страница 200: ...Setup and Installation 200 Optional modules 1 2 Version CND ...
Страница 201: ...Setup and Installation 201 Setup and Installation 1 2 ...
Страница 202: ...Setup and Installation 202 3 4 ...
Страница 203: ...Setup and Installation 203 5 6 ...
Страница 204: ...Setup and Installation 204 7 Opening the system 8 Removing the Motherboard MB ...
Страница 205: ...Setup and Installation 205 9 Lower modules Music EB 200 204 LAN interface and S0 ...
Страница 206: ...Setup and Installation 206 Version CND 10 Master and Satellite Modules ...
Страница 207: ...Setup and Installation 207 Version CND 11 Upper modules CTR UP0 E UP0 E EVM and EB 200 204 ...
Страница 208: ...Setup and Installation 208 Version CND 12 Baby Board VDC module ...
Страница 209: ...Setup and Installation 209 Version CND 13 Connections to the Motherboard MB ...
Страница 210: ...Setup and Installation 210 Version CND ...
Страница 211: ...Setup and Installation 211 14 Connections to the ADSL expansion boards ...
Страница 212: ...Setup and Installation 212 Version CND 15 Connections to the UP0 E module ...
Страница 213: ...Setup and Installation 213 Version CND 16 Connections to the lower EB 200 204 Music modules ...
Страница 214: ...Setup and Installation 214 Version CND 17 Connections to the S0 module ...
Страница 216: ...Setup and Installation 216 HiPath 1150 Package Contents ...
Страница 217: ...Setup and Installation 217 Setup and Installation 1 2 ...
Страница 218: ...Setup and Installation 218 3 Power Supply 4 ...
Страница 220: ...Setup and Installation 220 7 CTR UP0 E Module 8 EVM Module ...
Страница 221: ...Setup and Installation 221 9 Installing expansion and optional modules 10 ...
Страница 222: ...Setup and Installation 222 11 12 Power Supply ...
Страница 224: ...Setup and Installation 224 Installing the ADSL TME1 UP0 E and S0 modules 1 2 ...