background image

HiPath 1100

HiPath 1120
HiPath 1150
HiPath 1190

Analog MF Telephones

Programming Manual

Содержание HiPath 1100

Страница 1: ...HiPath 1100 HiPath 1120 HiPath 1150 HiPath 1190 Analog MF Telephones Programming Manual ...

Страница 2: ...ne sets Quick Reference Guide Analog and System Telephones This guide provides summarized information on how to use the different codes for the features of each system Attendant Console Quick Reference Guide This guide provides summarized information on how to use a system telephone as an Attendant Console Service Manual This manual contains information regarding Siemens distributors and Service C...

Страница 3: ...the system or dismantle any of the telephones If you have any problems ask for assistance from your System Administrator Care of the equipment Keep containers with liquids such as tea coffee soft drinks etc away from the system and telephones to prevent spillage This equipment conforms to the EU Directive 1999 5 EG as attested by the CE mark This device has been manufactured in accordance with our...

Страница 4: ...e handset or speaker An extension is calling When enabling certain functions and procedures a long beeping tone means the activation was successful When enabling certain functions and procedures short beeping tones mean the activation failed System support technician The system s support technician is generally the person responsible for programming your HiPath 1100 The sys tem s support technicia...

Страница 5: ... of external lines 23 Analog line attendants 24 Phonebook Speed Dial 26 Class of service COS 27 Denied list 27 Permission list 28 Default permission and denied lists 29 Permission for using speed dial numbers without COS analysis 31 Assigning a class of service COS 32 Special class of service for a blocked extension 34 COS changeover 36 Attendant console 36 Carrier selection mode LCR or ACS 37 War...

Страница 6: ...d attendant to answer a call on an external analog line 53 Programming an extension 53 Pickup groups 53 Alert ring timeout for Pickup groups 54 Call groups CG 54 Call forwarding within a Call group CG 55 UCD subscriber groups 56 Collect call barring for a UCD subscriber group 57 Message waiting for UCD queue 58 UCD queue size 58 Time for message waiting connection to a UCD queue 59 UCD overflow ca...

Страница 7: ...r 83 Collect call barring by extension 84 Type of equipment connected to the extension 85 Auto answering mode 85 Pulses for call charges on an analog extension 86 Timer for outgoing external calls 87 Activate Disable timer for outgoing external calls 87 Timeout for external calls 87 Activate Disable timeout for external calls 88 Defining timeout for external calls 89 Day to begin timeout 89 Answer...

Страница 8: ...nal calls via ISDN 104 Billing 105 Call charge unit 105 Multiplier for call charge factor 105 Call charge factor for extensions 106 Call charge value by extension 106 Call cost limit for an extension 107 Date for updating the call cost limit for an extension 107 Updating the software 108 Sw information 108 Local SW update 108 Activating a software update 109 Day for SW Update 109 Time for SW Updat...

Страница 9: ...lephone 126 Internal entrance telephone 126 Configuring an internal entrance telephone 126 Door lock 127 DIDs for entrance telephones 127 Permission to open the door 128 External door extension 129 Report 130 Ticket account codes 134 Account code type 135 Account code confirmation 135 Data transmission rate 136 25 digit suppression in CDR records 136 Call detail report for incoming calls 137 Call ...

Страница 10: ...gistration 160 Automatic MSN assignment via local carrier 161 Assignment of an MSN to attendants 161 Busy signal 163 Local area code filter 164 Country area code filter 164 ADSL expansion boards 165 ADSL Module 166 SLIMC SADSLIM LIMC and ADSLIM modules 166 Default configuration of the LAN interface 167 EVM module 167 Duration of greeting messages 168 Mailbox language 169 Max number of auto configu...

Страница 11: ...ent for the Sensor 180 Number dialed by sensor activation 181 Number of attempts for activating the sensor 181 DTMF signals for the sensor 182 Sensor message 182 Relay 183 Timer to deactivate the relay 184 External Ring for Activating the Relay 184 Interaction Center Smart 184 TAC Smart Telephony Advanced Control 185 HiPath 1100 Manager 186 HiPath 1100 ADSL Manager 188 Siemens Admin Console 188 Co...

Страница 12: ...9 Connections to the ADSL expansion boards 211 Connections to the UP0 E module 212 Connections to the lower EB 200 204 Music modules 213 Connections to the S0 module 214 Technical Data 215 HiPath 1150 216 Package Contents 216 Setup and Installation 217 Power Supply 218 View of Module Slots 219 CTR UP0 E Module 220 EVM Module 220 Installing expansion and optional modules 221 Example of a configurat...

Страница 13: ...iPoint ISDN adapter optiPoint phone adapter and op tiPoint acoustic adapter USB and V 24 adapter for system integration with applications such as CTI HiPath 1100 Manager billing etc Sensor and relay Hipath1120 only Expansion modules EB 202 2 analog trunks and 2 analog extensions EB 204 2 analog trunks and 4 analog extensions Hipath1120 only EB 206 2 analog trunks and 6 analog extensions EB 210 2 a...

Страница 14: ...iPath 1120 Makes it possible to play music for calls on hold The music input is provided by an external music source such as a radio connected to the system Æ page 98 This module also features a relay and a sensor for supporting additional devices such as entrance telephones door openers alarms etc Æ page 177 TFE entrance telephone Interface Makes it possible to connect an entrance telephone to an...

Страница 15: ...g extensions 8 10 KS system telephone interface1 4 8 8 Expansion modules2 EB 010 0 4 14 EB 012 0 3 11 EB 202 0 4 16 EB 204 2 0 EB 206 0 4 16 EB 210 0 4 11 EB 200 2 4 16 EB 400 0 3 10 EB 800 0 1 5 S0 module 1 2 TME1 module 0 1 2 UP0 E optiPoint module 1 1 or 2 CD 16 module KS 0 1 Optional modules ADSL expansion boards ADSL SLIMC SADSLIM LIMC and ADSLIM modules 1 EVM Module 1 Music module 1 on board...

Страница 16: ... for a maximum number of 32 lines we cannot have any additional analog line Example 2 HiPath 1150 slot 0 MB 210 slot 3 TME1 30 digital lines In this case there are 32 external lines at most available on the system This means there is no room for an additional EB module with an analog trunk 30 CAS S2 digital lines 2 MB analog trunks 32 external lines If an EB 200 were installed in slot 1 or slot 2 ...

Страница 17: ... E Module For the HiPath 1150 1 TME1 module 2 Motherboard 3 S0 module 4 Analog modules UP0 E Module For the HiPath 1190 1 TME1 module 2 Analog modules UP0 E Module 3 S0 module The instructions that follow refer to the factory default settings Description HiPath 1120 HiPath 1150 HiPath 1190 External line 801 to 808 801 to 832 801 to 845 Extension including S0 11 to 30 11 to 60 610 to 645 101 to 240...

Страница 18: ... the programming mode Brazil Correct entry 1 beep confirmation tone Incorrect entry 3 beeps The program will then re vert back to the initial screen of the programming mode After completing the programming steps the sys tem responds with a confirmation tone and finalizes the setting configuration The program will then re vert back to the initial screen of the programming mode Fax DID Virtual messa...

Страница 19: ...the programming mode After parameters are entered the equipment auto matically exits programming mode After configuring a setting press the key After configuring a setting wait approximately 5 seconds If no code or setting is entered the system will continue to wait for an entry or will assume that a null entry oc curred It will proceed to the next programming step depending on the code first ente...

Страница 20: ...hanged It is possible therefore to select a country with a different default language Ex ample Country Brazil Language English Required Programming mode must be activated 95 31994 ejh w Enter the programming code p w Select the language for displaying messages d Custom e Portuguese f Spanish g English default h French i Italian j Turkish w Initial status for programming mode Country group of count...

Страница 21: ...Spanish 02 Argentina Argentina Spanish 03 Portugal Portugal Portuguese 04 Chile Chile Spanish 05 Venezuela Venezuela Spanish 06 Mexico Mexico Spanish 07 Vietnam Vietnam English 08 IM Spanish Columbia Uruguay Ecuador Central America Indonesia2 Spanish English 09 IM English Saudi Arabia Bahrain Egypt United Arab Emirates Ghana Yemen Iran Jordan Kuwait Libya Nigeria Oman Kenya Zimbabwe Syria Sudan Ta...

Страница 22: ...tan English 18 Spain Spain Spanish 19 Russia Russia English 20 Ukraine Ukraine English 21 Peru Peru Spanish 22 China 2 China 2 English 23 Philippines Philippines English 24 Canada Canada English 25 South Africa South Africa English 26 Turkey Turkey English 27 Latvia Latvia English 28 Lithuania Lithuania English 29 Italy Italy English 30 Australia Australia English 31 United King dom United King do...

Страница 23: ...this key Initial status for programming mode Default access to a group of external lines This feature configures dialing 0 for each extension as the dialing method for a group of external lines The de fault external line access code is 0 Required Programming mode must be activated 95 31994 ddf w Enter the programming code p w Enter the extension number e g 11 101 p w Enter the number for the group...

Страница 24: ... mode must be activated 95 31994 ehf w Enter the programming code p w Enter a number for an analog trunk e g 801 e h Select the period of the day for answering calls e Day f Night g Day service second attendant h Night service second attendant Example 801 and 802 external lines are programmed as part of the 890 group of lines When using code 002 Extension 11 101 is as signed to group 890 This mean...

Страница 25: ...ng calls e Day f Night g Day service second attendant h Night service second attendant q w The selected line attendant will be deleted r w Press this key Initial status for programming mode If an extension is connected to a door opener de vice the device cannot be configured as an at tendant Within a subscriber group an incoming call rings at the first extension available according to the call dis...

Страница 26: ...honebook Required Programming mode must be activated 95 31994 eef w Enter the programming code ddd fhm w Enter the appropriate speed dial number abbreviated number p Enter the internal number Code 0 for an external line or the external line number e g 801 Then enter the external number up to 20 digits When the system is operating as a Satellite PABX first select a number for an external line e g 8...

Страница 27: ...ed lists 1 2 or 3 Æ page 27 Unrestricted trunk access total permission You can make all Class 7 external calls Denied list There are three lists of denied numbers that can be con figured with different telephone numbers and individual extension prefix combinations Denied list 1 COS 1 with 10 entries Denied list 2 COS 2 with 25 entries Denied list 3 COS 3 with 35 entries Telephones configured for r...

Страница 28: ...ber is entered after 5 seconds the con tent of that entry is removed w Initial status for programming mode Permission list There are three permission lists that can be configured with different telephone numbers and individual exten sion prefix combinations enter the number without the external access code Permission list 1 COS 4 with 10 entries Permission list 2 COS 5 with 25 entries Permission l...

Страница 29: ... from a permission list Required Programming mode must be activated 95 31994 efh w Enter the programming code h or i or j w Enter the number for the permission list of fi w Enter the list entry number of the number to be delet ed Wait 5 seconds If no new number is entered after 5 seconds the con tent of that entry is removed w Initial status for programming mode Default permission and denied lists...

Страница 30: ... 190 IM English French IM China Malaysia Singapore 999 995 1800 1608 571 Thailand 01 2 3 4 5 6 7 8 9 11 12 13 14 15 16 17 18 19 001 100 101 Greece 100 166 199 0800 090 India Pakistan Spain 091 112 1003 900 903 905 906 Russia 01 02 03 04 05 07 09 00 Ukraine Peru Country Permission list Denied list ...

Страница 31: ...peed dialing phonebook Required Programming mode must be activated 95 31994 Philippines Canada South Afri ca Turkey 0900 Latvia 01 03 112 02 04 0900 Lithuania 01 03 02 112 0900 Italy 112 115 113 118 0900 Australia 000 0900 France 3010 3040 3611 0800 0810 0820 0825 083605 3 08 00 026 0269 0508 0590 0594 0596 Korea 00 01 02 03 04 05 06 07 08 Country Permission list Denied list ...

Страница 32: ... day mode and another for night mode 1st digit defines the input for day service class 2nd digit defines the input for night service class Classes of service d Restricted e Outward restricted trunk access with Denied List 1 10 slots f Outward restricted trunk access with Denied List 2 25 slots g Outward restricted trunk access with Denied List 3 35 slots h Outward restricted trunk access with perm...

Страница 33: ...er the extensions e g 11 101 to which the COS se lected will be assigned r w Press this key Initial status for programming mode To assign a COS to additional lines repeat the program ming steps described above The default for all exten sions is 77 ...

Страница 34: ...ult setting for all exten sions e Outward restricted trunk access with Denied List 1 10 slots f Outward restricted trunk access with Denied List 2 25 slots g Outward restricted trunk access with Denied List 3 35 slots h Outward restricted trunk access with permis sion list 1 10 slots i Outward restricted trunk access with permis sion list 2 25 slots j Outward restricted trunk access with Permis si...

Страница 35: ... for maintaining the balance of the Classes of Ser vice used by an extension that is blocked or free This prevents an extension with a restricted ser vice from having free access when the lock is not activated and then keep an unrestricted category when the lock is activated ...

Страница 36: ...ode Attendant console The attendant console centralizes the flow of calls at up to two answering stations equipped with system tele phones with a display In the default configuration no at tendant console is configured Required Programming mode must be activated 95 31994 eid w Enter the programming code p w Enter an extension number for the attendant console e g 12 102 p w Enter the next extension...

Страница 37: ...tes that may be higher for that time of day This may be due to the unavailability of an external line for LCR Least Cost Routing When using a standard telephone a warning tone indi cates to the user that a different carrier is completing the call at this time When using a system telephone the carrier s name will show on the display Required Programming mode must be activated 95 31994 The attendant...

Страница 38: ... to the existing list for long national calls 3 For destination enter all area codes or partial area codes to cover all numbers within the country 4 Finally enter the time intervals in the time interval table With time intervals left empty the line of the default carrier will be occupied immediately 5 Select the line group on which calls will be made and the overflow line group to be used when the...

Страница 39: ...rrier type GSM or SIP Activating the time for LCR fallback This timer should be activated for routes subject to de lays or problems making call connections for example SIP boxes When the preset time has elapsed the call is routed to the Default Carrier defined in that rule of the LCR See Manager A31003 K1160 M810 LCR Required Programming mode must be activated 95 31994 fid w Enter the programming ...

Страница 40: ...s feature is useful for choosing the route destination with the best rate when he call is actually made or for setting a single route once the conversion rules are duly pro grammed The first digits of the number dialed by the user are an alyzed by the system If they match the conversion rule they will be replaced by the default number as set forth by that rule The route destination to be used can ...

Страница 41: ...al lines Programming allows access to an external line or group of external lines through a code other than 0 Required Programming mode must be activated 95 31994 eij w Enter the programming code d or lmd to lmm Enter the group code number default is 0 p w Enter a number for an external line e g 801 r w Press this key Initial status for programming mode Index Number Select ed Alterna tive number G...

Страница 42: ... lines the first group is the default setting Enter a number to specify the overflow group to be used d or lmd to lmm f All external line groups g None r w Press this key Initial status for programming mode Example 801 and 802 external lines are programmed as part of the 890 group of lines 890 When using code 002 Extension 11 101 is as signed to group 890 This means that when the 0 access code is ...

Страница 43: ...activated as first option g Analog trunks are activated as first option w Initial status for programming mode Analog trunk seizure protocol This feature specifies the protocol to be used by the system for seizing an analog trunk based on the local carrier s information Required Programming mode must be activated 95 31994 dek w Enter the programming code p w Enter a number for an analog trunk e g 8...

Страница 44: ...94 ddi w Enter the programming code w Enter a number for an analog trunk e g 801 d g Select the type of protocol d deactivated e DTMF1 f DTMF2 off hook g FSK p w Enter the next external line number or r w Press this key Initial status for programming mode When a Country setting is specified Country group of countries on page 20 the appropriate protocol is automatically selected Country Protocol Co...

Страница 45: ...e g w Enter the number for the type of access to an external line e bidirectional default f incoming unidirectional g outgoing unidirectional p w Enter the next external line number or r w Press this key Initial status for programming mode Flash duration on analog line The duration of the Flash signal that is sent by the sys tem to each analog trunk can be configured individually Flash signal dura...

Страница 46: ...900 ms w Initial status for programming mode Maximum time between rings for an incoming call This consists of the time interval between two call puls es from the local carrier approximately 6 seconds At the end of this time interval the system disconnects from the external line and gets ready to receive other calls In some countries the pause between pulses is longer than 6 seconds Here you can sp...

Страница 47: ...arrier and the PABX can be improved Required Programming mode must be activated 95 31994 ehk w Enter the programming code p w Enter a number for an analog trunk e g 801 e h w Enter the appropriate number for the type of external line For example in the case of Brazil it would be e standard 900 line Ω default f 600 line Ω g short line h long line p w Enter the next external line number or r w Press...

Страница 48: ...log trunk e g 801 d f w Enter the appropriate number for signaling type d None default e Polarity reversal f DTMF tone p w Enter the next number for the analog trunk or r w Press this key Initial status for programming mode When DTMF is selected you must program a tone A B C or D using Manager If a tone is not programmed using the Manager the switch de faults to tone A When using the GROUND option...

Страница 49: ...tomatically blocks this line With MF telephones the number dialed will be trans mitted to the external line approximately 4 to 5 seconds after the last digit was dialed 1A dialing Required Programming mode must be activated 95 31994 ejd w Enter the programming code p w Enter a number for an analog trunk e g 801 q or r w Activate Disable dial tone detection for an analog trunk q Activate default r ...

Страница 50: ...nd external access code This setting specifies the code used by the main PABX for accessing external lines This code is used to check if there is a dial tone at an external line and to generate a pause while dialing redialing or using the speed dial ing feature The default setting for the second code is 0 Required Programming mode must be activated 95 31994 egh w Enter the programming code When a ...

Страница 51: ...994 djg w Enter the programming code q or r w Activate Disable a false tone r Deactivated for Argentina Korea and India q Activated for all other countries default w Initial status for programming mode Internal access code for automatic seizure This features specifies the code to be used for making internal calls when an extension is configured for auto matic seizure of an external line Access cod...

Страница 52: ...nalog present System slots that are not connected to an external line should be configured as unavailable Required Programming mode must be activated 95 31994 dkm w Enter the programming code p w Enter a number for an external analog or digital line e g 801 q or r w Present Absence of an external line q Presence default r Absence r w Press this key Initial status for programming mode Country Code ...

Страница 53: ...p w Enter a number for an analog trunk e g 801 de fd Enter the activation timeout 01 to 20 in 5 second cy cles where 00 0 seconds 06 30 seconds de fault etc w Initial status for programming mode Programming an extension Pickup groups Extensions can be grouped into a maximum of 16 Pick up groups This allows an extension to answer calls that ring at other extensions belonging to the same Pickup grou...

Страница 54: ... for programming mode Alert ring timeout for Pickup groups If a call is not answered within a specified period of time a short alert ring is sent to the Pickup group see also Pickup groups Required Programming mode must be activated 95 31994 dgi w Enter the programming code dd im w Enter the length of time for the Alert Ring Signal 00 to 59 seconds or q w Disable the alert ring signal default w In...

Страница 55: ...70 to 779 q w All extensions belonging to the Call group selected are deleted r w Press this key Initial status for programming mode Call forwarding within a Call group CG This feature works only on digital lines It provides call forwarding for extensions belonging to Call groups When a call is routed to a Call group it rings at all exten sions at the same time The extension configured for call fo...

Страница 56: ...also view the UCD group call statistics using the Call Center software Interaction Center Smart Extensions can be grouped in a maximum of 10 UCD groups 790 to 799 In the default configuration no ex tensions are assigned to subscriber groups Required Programming mode must be activated 95 31994 dfg w Enter the programming code p w Enter the UCD subscriber group number 790 to 799 p w p w Enter the ex...

Страница 57: ...ed only at the moment they are answered The system bypasses collect call barring for members and non members of the group This means that collect call barring is only acknowledged Required Programming mode must be activated 95 31994 ddk w Enter the programming code p w Enter the UCD group number e g 790 q or r w Activate Disable collect call barring q Activate r Disable default p w Enter the next ...

Страница 58: ...atus for programming mode UCD queue size When all UCD group agents are busy or unavailable calls to a UCD group are placed on a waiting queue Calls are distributed among group members according to priority and waiting time on the queue Messages or music can be played for callers that are waiting This setting specifies the size of the UCD queue for each UCD group The default setting for UCD groups ...

Страница 59: ...9 in 5 second cycles where 00 0 seconds default 06 30 seconds etc p w Enter the next UCD subscriber group number or r w Press this key Initial status for programming mode UCD overflow call destination This setting specifies a call destination for each UCD group when All agents are logged out A UCD queue reaches the maximum number of calls waiting The queue s overflow timeout expires In the default...

Страница 60: ...Calls to agents This setting allows you to configure a round robin type distribution of calls so each call rings automatically at the station of the next available agent If no agents are logged in calls are forwarded to an overflow call desti nation Required Programming mode must be activated 95 31994 dfl w Enter the programming code p w Enter the UCD subscriber group number 790 to 799 q or r w Ac...

Страница 61: ... in 5 second cycles where 00 0 seconds default 06 30 seconds etc p w Enter the next UCD subscriber group number or r w Press this key Initial status for programming mode Ring Signal Timeout for agents This setting specifies how long an incoming call will keep on ringing at each agent s station before overflow occurs The default setting is 30 seconds Required Programming mode must be activated 95 3...

Страница 62: ... Press this key Initial status for programming mode Cascaded call forwarding This allows a call to be forwarded up to the third desti nation regardless of the type of call forwarding i e destination 1 has call forwarding to destination 2 and destination 2 has call forwarding to destination 3 Any call to destination 1 will be forwarded to destination 3 If destination 3 has call forwarding the opera...

Страница 63: ...wing situation Number 1 is set to forward to number 2 and number 2 is set to forward to number 3 Here the display can be configured as follows Last partner the caller display will show the follow ing forwarded to number 3 and number 3 display will indicate from number 1 First partner the caller display will show the follow ing forwarded to number 2 and number 3 display will indicate from number 2 ...

Страница 64: ... a queue 00 to 99 in cycles of 5 seconds where 00 0 seconds 06 30 seconds 12 1 minute default 99 8 min utes 15 seconds p w Enter the next UCD subscriber group number or r w Press this key Initial status for programming mode Waiting message before signaling a UCD call This feature allows you to connect a call waiting mes sage for incoming calls before they ring at a UCD exten sion Required Programm...

Страница 65: ...p is a group of extensions for answering calls directed to a specific number identifying the group When an extension does not answer an internal or external call within a specified period of time see Timeout within a Hunt group the call will ring consec utively at the extensions that are available within the group When there is no signal the extension may dis connect from the Hunt group Extensions...

Страница 66: ...ups This setting specifies how each Hunt group will conduct a search for an available extension linear search or round robin search A linear search always starts from the first extension in the group A round robin search starts after the last extension selected Required Programming mode must be activated 95 31994 dff w Enter the programming code p w Enter the Hunt group number 780 to 789 e or f w ...

Страница 67: ...rogramming mode Call forwarding within a Hunt group HG This feature only works for digital lines It provides call forwarding for extensions belonging to Hunt groups When a call is directed to a group it rings at each exten sion according to the group settings linear or round robin When an extension is set for call forwarding calls are routed to the destination as configured If a call is not answer...

Страница 68: ...rgent Call default w Initial status for programming mode Caller ID by name number This feature enables Caller ID information to be dis played on an extension s telephone display Required Programming mode must be activated 95 31994 dgm w Enter the programming code e g w Select the information to be shown on the display e Name and number default f Name only When the Call deflection on page 154 featu...

Страница 69: ... e with permission to override and sending warning tone p w Enter the next extension number or r w Press this key Initial status for programming mode Silent monitoring This feature allows an extension to override another ex tension without sending a warning signal to the parties having a conversation for certain countries only Required Programming mode must be activated 95 31994 dhj w Enter the pr...

Страница 70: ...et 4010 The telephone must have an external power supply and comply with the appropriate regulations Required Programming mode must be activated 95 31994 ded w Enter the programming code p w Enter the analog extension number e g 12 102 p w Select the type of configuration d no Caller ID default On Profiset 3030 telephones the MUTE option is automatically activated with Silent monitoring Within the...

Страница 71: ...ll is received and transferred to an extension with this feature is acti vated the external line number does not show on the display Example An analog extension receives an external call over an external line that belongs to group 890 number 24987049 When this feature is activated the display show only 24987049 When this feature is deactivated the display shows 89024987049 that is the number for t...

Страница 72: ... w Enter the programming code p w Enter the extension number e g 12 102 p w Enter a 5 digit password to set an electronic lock for the extension default is 00000 or q Delete the electronic lock password it defaults to 00000 w Initial status for programming mode Timeout for call forward no answer This feature specifies a timeout for the first attendant to answer an incoming call If the call is not ...

Страница 73: ...n is required for configuring a list Incoming caller ID Day of the week and time Type of call internal or external When more than one number have been specified for incoming calls to an extension the call forwarding prior ity will be 1 Checks to see if the Caller ID for the incoming call matches the number programmed for the extension 2 Checks to ensure that the Type of Call internal or ex ternal ...

Страница 74: ...nation configured if the extension is busy when the call is made Required Programming mode must be activated 95 31994 and call forward no answer must be activated as well eli w Enter the programming code p w Enter the extension number e g 12 102 Conditional call forwarding has priority over an unconditional call forwarding Conditional call forwarding is not available for S0 extensions function The...

Страница 75: ...g code p w Enter the extension number e g 12 102 q or r w To enable deactivate permission for external line call for warding q Activated default r Deactivated p w Enter the next extension number or r w Press this key Initial status for programming mode Dialing mode Urgent call and callback when busy facilities do not work when call forwarding busy and call for ward no answer are activated If the e...

Страница 76: ...e is the maximum period of time required by a PABX to detect a flash signal gener ated by an internal telephone If older MF dialing tele phones are connected to the system it may be neces sary to adjust the Flash detection time to their response times see manufacturer s instructions The specified Flash detection time may vary for different countries Required Programming mode must be activated 95 3...

Страница 77: ... code 42 By default the first extension of the system is config ured as the overflow extension for Busy signal or Wrong Number Required Programming mode must be activated 95 31994 egf w Enter the programming code e g w Choose a list for call forwarding e No answer f Busy g Wrong number p Enter the extension number e g 12 102 to be added to the list w Initial status for programming mode The system ...

Страница 78: ...de ehi w Enter the programming code p w Enter the extension number e g 12 102 to be as signed a Hotline mode p w Enter the speed dialing number you want to select e g 000 to 249 p w Enter the next extension number or r w Press this key Initial status for programming mode Disabling Hotline mode Required Programming mode must be activated 95 31994 ehi w Enter the programming code p w Enter the exten...

Страница 79: ...e phone key pad the call to the Hotline will be canceled Each extension can have a different timeout for enabling a Hotline This timeout may vary from 0 to 9 seconds By default the Hotline activation timeout is 0 seconds Required Programming mode must be activated 95 31994 ejf w Enter the programming code p w Enter the extension number except 11 101 for exam ple 12 102 for which you want to change...

Страница 80: ...w Enter an extension for the master telephone e g 11 101 p w p w Specify up to 15 extensions as secretary telephones e g 12 102 r w Press this key Initial status for programming mode Delete associated group Required Programming mode must be activated 95 31994 eie w Enter the programming code p w Enter an extension for the master telephone e g 11 101 q w The master telephone extension is deactivate...

Страница 81: ...xtension number e g 12 102 to be pro grammed q w Delete the CD assignment from the extension p w Enter the next number for the CD port and extension or Rr w Press this key Initial status for programming mode Extension coefficient If the impedance value or appropriate type of internal line is available the quality of transmission and recep tion can be improved Required Programming mode must be acti...

Страница 82: ...ceive signals generated by the voice mail server that indicate when there is a message wait ing in the user s mailbox This notification is sent using an FSK protocol Æ page 43 The signals are detected over an analog trunk by a voice mail server configured for this type of protocol For standard telephones with a display MWI will only be indicated if a CLIP is configured for the extension us ing opt...

Страница 83: ... mode or q Press this key to delete the extensions in the group r w Press this key to finalize the entry Initial status for programming mode Waiting Message Server Number This setting specifies an MSN number for the Waiting Message server By default no MSN is configured Required Programming mode must be activated 95 31994 dji w Enter the programming code The group must be activated to use this fea...

Страница 84: ... 31994 emg w Enter the programming code p w Enter the extension number e g 11 101 q or r w Activate Disable collect call barring q Activate r Disable default p w Enter the next extension number or r w Press this key Initial status for programming mode If a call has been answered at least once by the system collect call barring cancels the blocking If an incoming call over a digital line is forward...

Страница 85: ...ne g Music h External door extension i Voice mail p w Enter the next extension number ou r w Press this key Initial status for programming mode Auto answering mode This setting specifies the use of Auto answering mode for the telephone by using a feature code see functions used for Making Calls speakerphone Auto answering mode in the User Manual Required Programming mode must be activated 95 31994...

Страница 86: ...1994 dhe w Enter the programming code p w Enter the analog extension number e g 11 101 q or r w Activate Disable transmission of billing pulses q Activated r Deactivated default p w Enter the next analog extension number or r w Press this key Initial status for programming mode If the telephone does not have a microphone e g analog telephones optiPoint Entry and Ba sic the subscriber hears a busy ...

Страница 87: ... be activated 95 31994 dhk w Enter the programming code p w Enter the extension number e g 11 101 p w Enter the length of time for the duration of external calls for the specified extension 00000 to 17280 in 5 second cycles where 00 0 seconds 36 180 seconds de fault etc p w Enter the next extension number or r w Press this key Initial status for programming mode Activate Disable timer for outgoing...

Страница 88: ...nsion number e g 11 101 q or r w Activate Disable the timeout for external calls q Activated r Deactivated default w Initial status for programming mode Calls may also be interrupted if the extension has been configured with these features Timer for outgoing external calls Æ page 87 the timeout stops counting Billing Æ page 105 the call will only be started or can continue if the time and credit l...

Страница 89: ... default 00036 180 seconds etc p w Enter the next extension number or r w Press this key Initial status for programming mode Day to begin timeout This allows the user to define a day of the month on which the timeout for external calls on all extensions will begin The default setting for this feature is deactivated Required Programming mode must be activated 95 31994 fhe w Enter the programming co...

Страница 90: ...ust be activated 95 31994 dlf w Enter the programming code dde ehd w Enter MSN slot 001 140 de fd Enter the delay time 01 to 20 in cycles of 5 seconds where 00 0 seconds 06 30 seconds default etc w Initial status for programming mode MSN and extension assignment for ex ternal outgoing calls This allows a group extension to make outgoing calls using one of the selected MSNs In the default configura...

Страница 91: ...ncoming or outgoing to another external call Required Programming mode must be activated 95 31994 dme w Enter the programming code p w Enter the extension number e g 11 101 q or r w Activate deactivate transfer q Activated r Deactivated default r w Press this key Initial status for programming mode An external to external transfer can only be made when at least one of the lines is a digital line a...

Страница 92: ...pses Required Programming mode must be activated 95 31994 fel w Enter the programming code q or r w Activate Disable the timeout q Activated r Deactivated default w Initial status for programming mode Configuring a timeout for an external to external connection It allows configuring a timeout between two external calls when no other extension is involved in the call Call timeout can be set from 1 ...

Страница 93: ...after external to external transfer This option allows you to set a code to restart the time out period for disconnecting an external call This ap plies when at least one external line is an analog line and after a call has been transferred Code 091 or for warded 11 to an external destination by an authorized extension Required Programming mode must be activated 95 31994 elh w Enter the programmin...

Страница 94: ...rd no answer on page 72 fea ture programming code 130 or through the HiPath 1100 Manager Required Programming mode must be activated 95 31994 fek w Enter the programming code q or r w Activate deactivate transfer q Activated default r Deactivated w Initial status for programming mode Automatic Seizure of an external line This allows dialing an external call when the handset is lifted without using...

Страница 95: ...ion 0 Automatic ID is selected the ac tivation of this feature may impact the program ming of the Dialing mode It is recommended that you reconfigure the Dialing Mode Pulse or Tone for the extensions Only one external call can be made or one fea ture can be used at a time A feature that is activated during a call is deacti vated as soon as one of the parties hangs up TAPI only monitors physical po...

Страница 96: ...Activated r Deactivated default p w Enter the next extension number or r w Press this key Initial status for programming mode MSN DISA This specifies from which MSN the DISA features will operate In the default configuration no MSN is set Required Programming mode must be activated 95 31994 dem w Enter the programming code p w Enter an MSN up to 20 digits r w Press this key Initial status for prog...

Страница 97: ...this facility is available Required Programming mode must be activated 95 31994 dfd w Enter the programming code p w Enter the code for an analog trunk e g 801 e h w Select an answering timeout for DISA e Never default f Night only g Day only h Always p w Enter the next number for an analog trunk or r w Press this key Initial status for programming mode When an external digital line is used for th...

Страница 98: ...radio connected to an extension In order to accomplish this add extensions in two MOH groups or do not assign any extension Required Programming mode must be activated 95 31994 egj w Enter the programming code d h Enter the code for a music source d No music e Internal MIDI default f Internal WAVE g External h External extension w Initial status for programming mode Assigning extensions to MOH gro...

Страница 99: ... Music source for the MOH group When an extension has a call on hold the caller will hear the music programmed for that extension s group dll w Enter the programming code e or f Select group 1 or 2 q h Enter the code for a music source d No music e Internal MIDI default f Internal WAVE g External h External extension r w Press this key Initial status for programming mode Music source extension Thi...

Страница 100: ...ed from au dio equipment connected to an extension slot By default no extension is configured Required Programming mode must be activated 95 31994 djh w Enter the programming code p w Enter the extension number e g 11 101 or q w Deletes the music source extension w Initial status for programming mode Setting the time for an external room monitor This setting specifies a timeout for the automatic d...

Страница 101: ...e time setting This allows you to configure a pause P between MF digits This can be used when programming system and individual speed dialing system telephone programma ble keys or for enabling Suffix dialing This period of time can be set from 1 to 5 seconds The default setting is 2 seconds Required Programming mode must be activated 95 31994 ffk w Enter the programming code e i w Enter the lengt...

Страница 102: ...er or pressing the Redial Key using a system tele phone Each P character inserts a 2 second pause de fault in the connection A longer pause can be in serted by entering more than one character for example for a 4 second pause enter PP The first P or specifies that the next digits for A will only be forwarded if 1 digital line or S0 extension P DTMF digits are sent after local carrier iden tificati...

Страница 103: ...r the programming code p Enter the first digits up to 6 that are not supposed to be dialed when using a Caller List Wait 5 seconds w Wait for a confirmation tone Initial status for programming mode Date time manual setting The date and time can be shown on your system tele phone display It is important to set the correct time date for recording call details Required Programming mode must be activa...

Страница 104: ... configuring this setting an external ISDN call can schedule a Callback for the MSN number called Required Programming mode must be activated 95 31994 ffe w Enter the programming code q or r w Activate deactivate callback q Activate callback default r Disable callback w Initial status for programming mode When you restore the default setting 99 the date the SW was generated will be displayed The t...

Страница 105: ...ode must be activated 95 31994 emi w Enter the programming code p Set the call charge factor 9 digits p Enter the decimal separator position 0 to 3 Examples for R 0 12 000000012 and 2 comma position for R 2 00 00002 and 0 comma position for R 123456 789 123456789 and 3 comma po sition w Initial status for programming mode Multiplier for call charge factor This setting specifies the multiplier for ...

Страница 106: ... there is a factor for billing the users Required Programming mode must be activated 95 31994 dhg w Enter the programming code p w Enter the extension number e g 11 101 e g w Select a billing factor for the extension e Default equivalent to the billing value x1 default f Factor 1 g Factor 2 p w Enter the next extension number or r w Press this key Initial status for programming mode Call charge va...

Страница 107: ...cost limit for an extension This setting limits how much an extension has available for Call Charges Required Programming mode must be activated 95 31994 dhh w Enter the programming code p w Enter the extension number e g 11 101 q or r w Activate deactivate call charge limit q Activated r Deactivated default w Initial status for programming mode Date for updating the call cost limit for an ex tens...

Страница 108: ...de to view the name of the product e g HiPath 1150 q w Press the key to view additional information 1 Type of system 2 Release 3 Version 4 APS 5 Serial number r w Press this key Initial status for programming mode Local SW update This feature initiates the download of the last software version released for the PC and then downloads the up date for the exchange For this feature to work the system m...

Страница 109: ...t be activated 95 31994 dii w Enter the programming code q or r w Activate deactivate software update q Activated r Deactivated default w Initial status for programming mode Day for SW Update This setting specifies a day for starting the data transfer The default setting for the update to start is day 01 Required Programming mode must be activated 95 31994 dih w Enter the programming code de ge En...

Страница 110: ...te the software The default configuration does not specify any number Required Programming mode must be activated 95 31994 dij w Enter the programming code p w Enter the external numbers up to 20 digits r w Press this key to finalize the entry Initial status for programming mode Frequency for SW Update This setting specifies regular intervals in months for transferring data During a transfer the t...

Страница 111: ...General settings 111 Step by step w Initial status for programming mode ...

Страница 112: ...rting the uploads w Initial status for programming mode Setting a System Password Access to the system s programming mode is protect ed by password to prevent unauthorized access The default password is 31994 This password can be changed Required Programming mode must be activated 95 31994 eld w Enter the programming code p w Enter a new system password 5 digits p w Confirm the new password by ent...

Страница 113: ... figured Required Programming mode must be activated 95 31994 emm w Enter the programming code p Enter the system password default is 31994 w The system restarts HiPath 1120 Alarms You can assign an alarm to a system sensor When the alarm is triggered the system dials the number stored as entry 249 in the speed dialing phonebook the name assigned to this entry can be up to 15 characters long For e...

Страница 114: ...amming of the Sensor and Relay for the HiPath 1120 Relay and sensor on the Hi Path 1120 Emergency numbers You can specify up to five emergency numbers When one of these numbers is dialed and all external lines are busy the call on the first external line will be interrupted and the line used for making the emergency call Only an incoming call over an analog external line will not be disconnected R...

Страница 115: ...activated 95 31994 dje w Enter the programming code dd fd Enter the slots for the new modules Country Emergency num bers Name Brazil 190 193 Police Fire Department Portugal 112 Emergency Spain 112 Emergency Latvia 01 02 03 04 112 Lithuania 01 02 03 112 Italy 112 113 115 118 Australia 000 Emergency England 999 112 Emergency Servic es France 15 17 18 112 115 SAMU Police Fire Department Emergency Kor...

Страница 116: ...ing pattern will be 801 and 802 for analog trunks and from 11 to 20 for analog extensions When a S0 is added you have 803 to 806 for the digital lines 21 to 25 for S0 extensions Example 2 for a HiPath 1190 system MB EB 210 S0 5 ports 801 to 802 analog trunks 101 to 110 analog extensions 803 to 812 S0 digital lines 111 to 115 S0 extensions If a specific slot is selected 01 to 20 the previous num be...

Страница 117: ...e carried out remotely over external digital ISDN lines and analog lines via modem Required Programming mode must be activated 95 31994 dlh w Enter the programming code e or f w Select the operating mode e Via ISDN default f Via modem w Initial status for programming mode Activating remote administration This setting allows the system to be administered re motely Required Programming mode must be ...

Страница 118: ...r or r w Press this key Initial status for programming mode remote administration password This feature assigns a password for enabling remote ad ministration using a specified external number Service MSN The default configuration does not specify a password Required Programming mode must be activated 95 31994 djl w Enter the programming code e h Select a slot for the external number 1 to 4 p w En...

Страница 119: ...tings 119 Step by step Required Programming mode must be activated 95 31994 djm w Enter the programming code dde ehd w Enter MSN slot 001 140 or q w Press the key to remove it w Initial status for programming mode ...

Страница 120: ... Enter the programming code q or r Activate deactivate remote configuration q Activate remote configuration default r Disable remote configuration default w Initial status for programming mode t Replace the handset Example Remote configuration must be activated and the programming extension must have a conversation in progress on the external line over which program ming is to be performed qmme w ...

Страница 121: ... connected directly to the sys tem Ending remote administration Required The remote telephone is in programming mode emj w Enter the programming code using the remote MF tele phone This allows the system to free the external line and the MF code receiver t Replace the handset Type of MSN signal This setting lets you choose one of the four types of rings for various calls and a ring for registered ...

Страница 122: ...make a call in the User Manual Required Programming mode must be activated 95 31994 dmg w Enter the programming code p w Enter the MSN number selected Example User is at his her office 3416496 e This setting specifies an MSN for other facilities e g 3415565 f This setting specifies MSN slot 001 140 for other facilities for example 001 w Initial status for programming mode t Replace the handset At ...

Страница 123: ...ou to specify a password so that all incoming calls from a remote HiPath 1100 Manager that provides the correct password can be authorized to ex ecute remote administration In the default configura tion no password is set Required Programming mode must be activated 95 31994 ffd w Enter the programming code p w Enter an access code consisting of a maximum of 5 dig its w Initial status for programmi...

Страница 124: ...opti Point key module or optiPoint BLF to an optiPoint 500 telephone set or enabling a virtual keypad See User Manual A31003 K1160 B802 on the system tele phone KS Required Programming mode must be activated 95 31994 ejj w Enter the programming code w Initial status for programming mode If this code is used all the programmed keys of the disconnected consoles will be lost ...

Страница 125: ...31994 fhj w Enter the programming code de eg Enter the code of the profile de Analog extensions df Analog trunks dg optiPoint extensions dh KS extensions di ISDN telephones dj ISDN trunks dk Voice mail dl CLIP FDW dm Internal connections ed Sensor Relay ee ISDN CAS Layer 3 ef ISDN Layers 1 and 2 eg optiPoint Layers 1 and 2 or q w Press the key to delete the current configuration or Wait 5s w Initi...

Страница 126: ...es in extension slots Each entrance telephone must be individually activated in the system Required Programming mode must be activated 95 31994 eei w Enter the programming code e fd w Select a slot for the entrance telephone extension 1 to 20 p w Enter the analog extension number e g 12 102 to be activated as an entrance telephone p w Repeat these steps for any additional slot or r w Press this ke...

Страница 127: ...onal slot or r w Press this key Initial status for programming mode DIDs for entrance telephones It specifies the extensions that will be called during day or night service when the entrance telephone is activat ed The default setting is extension 11 101 Required Programming mode must be activated 95 31994 eim w Enter the programming code e fd w Enter the slot for the entrance telephone interface ...

Страница 128: ...o 20 e or f Select a period of time e Day f Night q w Delete DID extensions r w Press this key Initial status for programming mode Permission to open the door If there is a locking device installed in given slots in the internal entrance telephone permission will be required for opening the door in the required slots This class of service is assigned to all extensions by de fault Required Programm...

Страница 129: ...nsion is defined during the programming phase of Type of equipment con nected to the extension Æ page 85 code 003 These devices are connected directly to analog ports A B or in the bar of the S0 module as follows The external analog entrance telephone device must behave like an analog telephone dialing de tection and DTMF control The ISDN external door extension device must be have like an ISDN te...

Страница 130: ...r Terminal the HiPath 1100 provides local control of ticket purchasing at any time through a series of commands that can be pro grammed into the application interface with the switch Interface commands Command Description nticket_start n This command will be sent by the user Application to the PABX re questing that the stored tickets start being sent nticket_stop n This command will be sent by the...

Страница 131: ...administration can be performed via USB connec tion optiPoint ISDN or analog modem Tickets will only be shown after the end of the first connection Disconnect HyperTerminal to establish a serial or ADSL connection to the HiPath 1100 Manager Command Description nend of tick ets n This answer will be sent by the PABX to the Application interface when no stored tickets are left to be transmitted This...

Страница 132: ...st four digits of the number can be replaced with a If ADSL Connection mode is not being used to issue tickets we recommend that you deactivate the Cable Printing checkbox in the HiPath1100 Man ager To provide accurate call details you must update the system s time and date information Æ page 103 External line Ln Field 801 00 802 01 If the extension is programmed with the Call de flection feature ...

Страница 133: ...COS Ring Duration Number I Callfees Acc Code 22 11 99 14 00 00 01 21 00 14 00 01 34 2222222 1 In the event of a power outage during ticketing all tickets that were being sent when the power outage occurred are resent when a connection is established once again Example If 300 tickets are stored in the memory then 1 The user establishes a new connection sends 100 tickets and terminates the connectio...

Страница 134: ...de in the If account codes have not been configured in advance using the HiPath 1100 Manager See account codes A31003 K1270 M100 only ten digit account codes will be accepted in analog and S0 telephones Other wise the call will not be completed Required Programming mode must be activated 95 31994 dmi w Enter the programming code q or r w Activate Deactivate sending account code for call detail rep...

Страница 135: ... 31994 fhg w Enter the programming code e or f w Account code type e Optional default f Mandatory w Initial status for programming mode Account code confirmation When account code confirmation is activated only ac count codes that have been configured previously may be used account codes must be set using HiPath 1100 Manager If an invalid account code is typed in a neg ative tone will sound or a m...

Страница 136: ...transmission Baud rate e 9600 Baud f 14400 Baud g 19200 Baud default h 38400 Baud i 56000 Baud j 57600 Baud k 115200 Baud l 128000 Baud m 256000 Baud w Initial status for programming mode 25 digit suppression in CDR records The last digits dialed in an external call can be sup pressed in the data output They will be replaced by the symbol By default no digit is suppressed Required Programming mode...

Страница 137: ...re recorded at the end of the call default f Outgoing calls are recorded at the end of the call g Outgoing calls are recorded at the end of the call Incoming calls with Caller ID at the source are recorded at the beginning of the call Incoming calls with or without Caller ID at the source are recorded at the end of the call h Outgoing calls are recorded at the end of the call Incoming calls with C...

Страница 138: ...nds w Wait for a confirmation tone Initial status for programming mode Call detail report through serial inter face This setting specifies whether call detail report will be done through a serial interface or a modem Required Programming mode must be activated 95 31994 ddj w Enter the programming code q or r w Activate Deactivate call detail report through a serial in terface q Activated r Deactiv...

Страница 139: ...ension see call for warding in the User Manual Fax mode In this operating mode the system detects only Fax sig nals A greeting message is played for all incoming ex ternal calls If the caller wants to send a fax it can be sent at the end of the greeting If no fax signal is detect ed within 10 seconds of the greeting message a sec ond message is played and the call is transferred to an attendant DI...

Страница 140: ...age You have reached Siemens Your call is being transferred Auto Fax mode When this mode is activated the system can detect a fax signal during the first ten seconds of a conversation then transfer the call to a specified extension such as a Fax DID When no signal is detected the conversation proceeds as usual Answering menu The HiPath 1100 lets you create a customized call an swering menu transfe...

Страница 141: ...tial status for programming mode Recording a greeting The system provides a feature for recording announce ments for auto answering call transfers and alarms The recording is done using the handset We suggest that you record your greeting in a quiet environment You can check the recorded greeting by playing it back You can record a different greeting for each connection state To ensure proper oper...

Страница 142: ...eting announcement for business hours maximum of 32 seconds dl Fax DID Mode Greeting announcement for night service maximum of 32 seconds dm FAX DID Mode call forwarding announce ment maximum of 16 seconds ed Caller ID Announcement Mode maximum of 16 seconds ee Alarm announcement only HiPath 1120 max imum 8 seconds ef Reservation s Speak directly into the handset to record a greeting Or listen to ...

Страница 143: ...the operating mode for the line d deactivated e Fax f Attendant g Fax DID h Greeting i Auto Fax p w Enter the number for the next external line available or r w Press this key Initial status for programming mode To deactivate Required Programming mode must be activated 95 31994 efk w Enter the programming code p w Enter a number for an external analog or digital line e g 801 d Enter the code to de...

Страница 144: ... 102 p w Enter the number for the next external line available or r w Press this key Initial status for programming mode Deleting Fax Reception Extensions Required Programming mode must be activated 95 31994 efl w Enter the programming code p w Enter a number for an external line e g 801 assigned to Fax Reception q w The Fax extension selected is removed p w If necessary enter the number for the n...

Страница 145: ...e programming code e h w Select an operating mode for the Fax DID Module e Fax f Attendant g Fax DID h Greeting message q or r w Activate Deactivate collect call barring for the selected mode q Activate r Deactivate default p w Enter the next operating mode or r w Press this key Initial status for programming mode If a call has been answered at least once by the system collect call barring cancels...

Страница 146: ...Auto Fax p w Enter next MSN or r w Press this key Initial status for programming mode Fax extension for MSN After detecting a fax signal the Fax DID module can transfer a call to a Fax extension The DID Mode does not need to be configured for this feature Required Programming mode must be activated 95 31994 dle w Enter the programming code dde ehd w Enter MSN slot 001 140 p w Enter the extension n...

Страница 147: ...Of course if a Fax DID channel becomes available in the mean time the call will be answered as usual and the tim eout will be ignored However if the time specified for this setting is longer than the local carrier s timeout 1 5 minutes for Brazil the call will be disconnected by the local carrier before the PABX can forward it to an atten dant In the case of a digital line E1 CAS S2 or S0 access t...

Страница 148: ...120 can be equipped with a 2 port module the HiPath 1150 with a 2 port module or one 5 port module and the HiPath 1190 with two 2 or 5 port modules When only ISDN digital lines are being used the follow ing functions must be configured DID external number registration area code country code When the Fax DID module answers calls it plays one of the twelve greeting messages recorded unless it is wai...

Страница 149: ...by 2 The connection must be PP or PMP If it has been previously configured as S0 Bus line the connection will be automatically re versed to PP which is the default Extension only Each port will decrease the exten sion number slots by 1 The connection must be a S0 Bus line If it has been previously configured as PP or PMP the connection will be automatically re versed to S0 Bus line Required Progra...

Страница 150: ...n of the Port 00 is only for the external line PP or PMP dd dh For the HiPath 1150 dd dh For the HiPath 1190 For the second module place position 11 and port from 00 04 e g w Select the type of connection for the external digital line e Point to Point PP default for the first port f Point to Multipoint PMP g Bus S0 line call default for all other ports p Key in the physical slot of the port in the...

Страница 151: ...ine PP or PMP dd dh For the HiPath 1150 dd dh For the HiPath 1190 For the second module place position 11 and port from 00 04 q or r w Select the mode of the call q Asymmetric r Symmetric default w Initial status for programming mode No ACK Setup for S0 line Check with your local carrier to find out which operating mode should be configured for your system Required Programming mode must be activat...

Страница 152: ...mode must be activated 95 31994 dkj w Enter the programming code de df Type in the S0 module slot on the system1 dg or ee p Enter the slot for the S0 module slot dd de For the HiPath 1120 The Position of port 00 is only for the external line PP or PMP dd dh For the HiPath 1150 dd dh For the HiPath 1190 For the second module place position 11 and port from 00 04 q or r w Activate deactivate notify ...

Страница 153: ... carrier to calls made to digital lines By default all digital lines are assigned to MSNs Required Programming mode must be activated 95 31994 dkl w Enter the programming code dde ehd w Enter MSN slot 001 140 p w Enter a number for an external digital line e g 801 dde ehd w Enter the next MSN position or r w Press this key Initial status for programming mode Deleting assigned external lines Requir...

Страница 154: ...feature is available and provided by a local carrier an incoming call to an extension activated with call forwarding 11 is routed directly to an external destination over the public network Alternatively the HiPath 1100 system can be used Required Programming mode must be activated 95 31994 ffm w Enter the programming code q or r w To activate deactivate call deflection over the public net work q ...

Страница 155: ...q Activated r Deactivated w Initial status for programming mode When there is an incoming call to an extension activated for external call forwarding the system sends information about the call s new destina tion and the number of the forwarded extension to the public network This is done by means of a call deflection activation message The call is forwarded over the public network which means tha...

Страница 156: ...0 For the second module place position 11 and port from 00 04 q or r w Activate deactivate layer q Activated r Deactivated w Initial status for programming mode B Channel Allows you to change some default ISDN settings for specified countries Required Programming mode must be activated 95 31994 edg w Enter the programming code p Enter the S0 module slot on the system df For the HiPath 1120 dg For ...

Страница 157: ...rwise only the number of the MSN Attendant of the PABX will be made available In the default configuration this option is activated for the following countries Australia Greece and the Neth erlands Required Programming mode must be activated 95 31994 fhm w Enter the programming code p Enter the S0 module slot on the system df For the HiPath 1120 dg For the HiPath 1150 de and ee For the HiPath 1190...

Страница 158: ...guration procedure using the S2M Maintenance tool When the total number of digital trunks config ured for the module plus the number of analog trunks exceeds the maximum capacity of the system the analog trunks for the EB 202 206 and 210 expansion modules are deactivated Nevertheless the extensions will continue to work as usual Lines are deactivated in the order that they are physically installed...

Страница 159: ...well as a capability for sharing ap plications such as video conferencing or Internet ac cess Depending on whether your carrier has activated them some features such as Calling Line Identification Presentation CLIP and Malicious Call Identification MCID Calling Line Identification Restriction CLIR among others may be provided The HiPath 1150 can be equipped with one TME1 module configured for up t...

Страница 160: ... status for programming mode External number registration To use the attendant feature each MSN must be regis tered to a specific slot If the prefix Code 089 for these numbers has already been configured only the final digits need to be regis tered By default no digits are specified Required Programming mode must be activated 95 31994 eme w Enter the programming code dde ehd w Enter a slot 001 140...

Страница 161: ...gional Settings If the operating mode is PP Point to Point only the system number will be registered You must configure MSN numbers Ba sic MSN Settings Any MSN number previously configured must be deleted Assignment of an MSN to attendants MSNs registered for each slot see MSN and extension assignment for external outgoing calls code 086 must be assigned to extensions call groups or a mail box usi...

Страница 162: ...p to 10 extensions per group For example 11 770 780 or 790 or EVM Virtual port for example 744 dde ehd w Enter the next slot or r w Press this key Initial status for programming mode Deleting an extension number Required Programming mode must be activated 95 31994 emf w Enter the programming code dde ehd w Enter the external number slot q w Press the key to remove it dde ehd w Enter the next slot ...

Страница 163: ...er will think that the called per son is busy at the moment Required Programming mode must be activated 95 31994 ddh w Enter the programming code dde ehd w Enter the slot for the MSN number e or f w Choose a period of time for the assignment of MSN to extensions e Day f Night dde ehd w Enter the slot for the group with a busy signal dde ehd w Enter the next slot for the group with a busy signal or...

Страница 164: ...ing mode Country area code filter When a call is received the country area code CAC serves as a filter for the entry number and determines its type Required Programming mode must be activated 95 31994 def w Enter the programming code p w Enter the country area code up to 10 digits according to the table below r w Press this key Initial status for programming mode Country CAC Country CAC Brazil 55 ...

Страница 165: ...s etc ADSL modem access must be activated by a carrier for one of the lines An Internet provider is also required IM French South Africa 27 China 86 Turkey 90 Malaysia 60 Latvia 371 Singapore 65 Lithuania 370 Thailand 66 Italy 39 Greece 30 Australia 61 France 33 England 44 Korea 82 Do not connect the V 24 interface cable to the PABX when using a network interface module All data is delivered throu...

Страница 166: ... on the board HiPath 1120 SLIMC module LAN and SADSLIM module LAN ADSL modem HiPath 1150 1190 LIMC module LAN and AD SLIM module LAN ADSL modem These modules already have the CommServer applica tion installed and do not need to be connected directly to a PC to administer the PABX only to the LAN To set the required parameters of the modules use the Configuring the SpeedStream 4100 modem Æ page 190...

Страница 167: ...amming code w Initial status for programming mode EVM module EVM Entry voice mail is a voice mail solution for HiPath 1100 systems Its features are controlled through he keys on a system telephone or any type of equipment with MF dialing capability EVM is configured and activated by technical personnel through the HiPath 1100 Manager administration soft ware or a programming extension Feature Over...

Страница 168: ...ge Memory overload alert when it exceeds 80 Duration of greeting messages This setting determines a time period within which the caller can record a greeting message Required Programming mode must be activated 95 31994 fdd w Enter the programming code de di Enter the time available for the caller to record a mes sage 1 to 5 minutes The default setting is 2 minutes w Initial status for programming ...

Страница 169: ... countries as shown on the table below e g 06 for Portuguese w The system restarts after the change is made Language Code Table for EVM Code Language Default 01 German 02 English other countries 03 French IM French 04 Dutch 05 Italian 06 Portuguese Portugal and Brazil 07 Spanish Spain Argentina and IM Spanish 08 Czech 09 Slovenian 10 Polish 11 Rumanian 12 Greek Greece 13 Estonian 14 Latvia 15 Lith...

Страница 170: ...o configuration For example if there are 12 mail boxes and 10 have been configured through HiPath 1100 Manager only 2 boxes will be available for config uration by the user Required Programming mode must be activated 95 31994 fdf w Enter the programming code de fh Enter the number of auto configurable mailboxes de fault setting is 12 20 English US 21 Spanish INT 22 French Can ada 23 Korean 24 Flem...

Страница 171: ...on number e g 12 102 that you wish to associate to a mailbox or if you are using attendants for MSN numbers the EVM Virtual port 744 to 747 for example 744 that will be associated r w Press this key Initial status for programming mode Mailbox password Associates a password to a specific mailbox The de fault password is 1234 Required Programming mode must be activated 95 31994 fdh w Enter the progr...

Страница 172: ...ng mode Type of greeting for a mailbox This option determines the type of greeting to be used for a specific mailbox In the Manual option select the Type of Greeting 1 or 2 that was specified for the mailbox in Mailbox greeting configuration code 207 For the Day Night option the following settings should apply Greeting 1 Day Greeting 2 Night Required Programming mode must be activated 95 31994 fdj...

Страница 173: ...lect the type of greeting e Greeting 1 Day default f Greeting 2 Night r w Press this key Initial status for programming mode Message source This setting assigns a message to one of the two EVM ports Alternatively the message can be assigned to an MSN Required Programming mode must be activated 95 31994 fdl w Enter the programming code e or f Select a Message e Greeting 1 f Greeting 2 khme or khmf ...

Страница 174: ...itial status for programming mode Message for MSN This setting specifies whether a message will be played for a specific MSN Required Programming mode must be activated 95 31994 fed w Enter the programming code dde ehd w Enter MSN slot 001 140 e or f Select a Message e Greeting 1 f Greeting 2 r w Press this key Initial status for programming mode System number This setting specifies the HiPath 110...

Страница 175: ...de must be activated 95 31994 fef w Enter the programming code e h Select the type of number to be sent e Unknown default for other countries f System number default for Italy g Local Area Code LAC h Country Area Code CAC w Initial status for programming mode Type of voice mail This setting specifies the type of voice mail to be used by the system Required Programming mode must be activated 95 319...

Страница 176: ... auto answering slots Required Programming mode must be activated 95 31994 fej w Enter the programming code e or f Enter the number of the mailbox you would like to se lect khme or khmf Enter a greeting port for auto answering r w Press this key Initial status for programming mode Audio quality This setting specifies the audio quality for playing back greetings and messages Required Programming mo...

Страница 177: ...vated 95 31994 fgd w Enter the programming code p w Enter a number for an analog trunk e g 801 e or f Select a Message e Greeting 1 f Greeting 2 r w Press this key Initial status for programming mode Relay and sensor on the HiPath 1120 You can connect a music module to the HiPath 1120 system This module also provides a Relay and a Sensor for integrating other devices such as an entrance tele phone...

Страница 178: ...Path 1120 178 Dialing a number from the speed dialing directory and enabling a relay Sending a message with the EVM Module The activation logic based on the initial position of the sensor contacts and its resulting actions are program mable ...

Страница 179: ... number that was called must acknowl edge or ignore an alarm call by sending an acknowledgement code DTMF signal r w Press this key Initial status for programming mode Sensor activation logic The main position of the sensor can be set as follows Contacts are closed The sensor is activated when contacts are open Contacts are open The sensor is activated when contacts are closed Required Programming...

Страница 180: ...rogramming mode MSN Assignment for the Sensor This settings specifies an MSN for the system to be used for outgoing calls By using this MSN the called party is able to identify the origin of the call For in stance this would be the case for an alarm The default configuration does not specify an MSN Required Programming mode must be activated 95 31994 die w Enter the programming code dde ehd w Ente...

Страница 181: ...if w Enter the programming code p w Enter the number to be called up to 20 digits w Initial status for programming mode Number of attempts for activating the sensor This setting specifies the number of call attempts be tween 1 and 100 for the number specified in Number dialed by sensor activation see also Time between at tempts for activating the sensor An attempt is made after every call that was...

Страница 182: ...rogramming mode must be activated 95 31994 ekk w Enter the programming code p w Enter the number sequence up to 20 digits r w Press this key Initial status for programming mode Sensor message After assigning a number you can assign a message to the sensor This message will be transmitted to the as signed number when the sensor status is changed Required Programming mode is activated 95 31994 and a...

Страница 183: ...scellaneous functions Relay in the User Manual f Monoflop The relay is closed for a specified length of time Alternatively the relay can also be opened before the set time by entering the prop er feature code see Miscellaneous functions Relay in the User Manual g Invert The current status of the relay is reversed when the feature code to activate the Relay is selected at an extension h Music on Ho...

Страница 184: ...for programming mode Interaction Center Smart Interaction Center Smart is a Call Center solution that al lows supervisors to monitor and track one or more UCD groups of up to 10 agents each providing real time data that includes agent status support statistics by group or by agent and other types of information to help man age a Call Center With the Smart solution you can determine the number of c...

Страница 185: ...elephone by using a Windows interface make calls answer and transfer calls call forwarding and so on Analog extension With TAC Smart analog extension users have access to various facilities that up to now were only available to system telephone users Caller ID being one of them Fast access Each user can create a list of most fre quently used extensions and make calls simply by se lecting one The u...

Страница 186: ...ace a V 24 interface Remotely using a LAN when a computer of the network is connected to the HiPath 1100 via serial interface USB interface or ADSL module Considerations The HiPath 1100 Version 7 0 application installa tion overwrites the installation of previous ver sions of applications During the installation pro cess no messages are displayed to warn the user that previous versions of HiPath 1...

Страница 187: ...re the database with the system s settings Read the HiPath 1100 Manager Help file before pro ceeding with this operation If the database has previously been saved in an earlier version HiPath 1100 V5 1 5 2 or V6 0 and you want to update the database to HiPath 1100 V7 0 all you need to do is restore the bup file and the system will perform an automatic up date Once the restore process is completed ...

Страница 188: ...see the topics in the Help file of the HiPath 1100 ADSL Manager software Siemens Admin Console This is an administrative program for programming SLIMC SADSLIM LIMC and ADSLIM modules The modules can be configured by accessing their IP number Default 192 168 254 253 from your web browser http 192 168 254 253 Microsoft Internet Ex plorer or Netscape Navigator V 5 0 higher The Siemens Admin Console p...

Страница 189: ... check box if you wish to delete the previous settings of the module when you update Network Tab Shows information on the internal configuration of the module LAN shows the current configuration and allows you to change parameters IP address Netmask Gateway and DHCP Client number Hosts shows the IP addresses and the name of the Hosts set in the module and also allows you to add or remove existing ...

Страница 190: ...r DNS user name and password of the provider Administration of the TME1 mod ule Administration of the module TME1 can be made with E1 CAS access or S2 access For each access mode there is a tool for configuring the module E1 Trunk Manager E1 CAS access S2M Maintenance for S2 access Hardware Requirements Serial interface communications COM port E1 Trunk Manager You can use the administration progra...

Страница 191: ...cluding total costs per extension sector group in addition to traffic reports for both outgoing and incoming calls All the information is specified in the CallReport data base and can be manipulated by the user logged in as Administrator The availability of administrative softwares Hi Path 1100 Manager HiPath 1100 ADSL Manager S2M software and E1 Trunk Manager for our cli ents is subject to underg...

Страница 192: ...alling extension Required item Fixed size 6 DTMF signals Format i i calling extension External call format always Note if an extension is longer the DTMF digit in the protocol is replaced by the additional extension digit 3 Extension called Required element for calls Type 3 and 4 This element remains blank for all other types of calls Fixed size 6 DTMF signals Format i i extension called Note if a...

Страница 193: ...ernal call from Extension 10015 to Exten sion 10011 forwarded to the VMIe group configured as second attendant 4 10015 10011 1 Voice mail Protocol for the system The voice mail signals to indicate when there is a mes sage waiting at an extension s mailbox For this purpose it uses a DTMF service code 68 followed by the ex tension number When a message is erased a different DTMF code 68 is used to d...

Страница 194: ...eport for incoming calls 137 Call detail report manager 130 Call detail report through serial interface 138 Call forwarding configured for Call group ringing 55 Call forwarding within a Hunt group HG 67 Call groups CG 54 Call Report 191 Callback for external calls via ISDN 104 Callback urgent call activation for timeout 68 Caller ID 70 by name or number 68 Caller ID by name number 122 Caller ID on...

Страница 195: ...ing for a mailbox 172 Example for LCR settings on a local net work 38 Extension coefficient 81 External analog present 52 External CFW 74 75 External line call direction 45 External line prefix 160 External line settings 41 External music source extension assign ment 100 External MWI 82 enabling external message waiting indi cator 82 group 83 server number 83 External number registration 160 Exter...

Страница 196: ...ension 77 Overflow for groups external lines 42 Override 69 P PABX Trace log 125 Permission for using numbers speed dialing without COS analysis 31 Permission list 28 Phonebook Speed Dial 26 Pickup groups 53 Programming an extension 53 Programming codes summary 230 Programming mode 17 Pulses for call charges on an analog exten sion 86 R Recording a greeting 141 Relay 183 timer to deactivate the re...

Страница 197: ... for call forwarding no answer 72 Timeout for external calls 87 88 Day to begin 89 defining the time 89 Timer for outgoing external calls 87 Timer for outgoing external calls enabling deactivating 87 TME1 158 Type of answering signal 48 Type of equipment connected to the extension 85 Type of MSN signal 121 Type of voice mail 175 Types of caller lists 102 U UCD group Call Waiting message for UCD qu...

Страница 198: ...ty lock on the main distributing frame of the HiPath 1150 Protect against flood flammable materials excessive dust vibration and mechanical stress Do not install the system where there is a risk of exposure to sunlight humidity heating or cooling sources or proximity to electrical cabling Avoid placing the equipment near data transmission equipment elec trical soldering devices copy machines PCs a...

Страница 199: ...Setup and Installation 199 Required Tools HiPath 1120 Package Contents ...

Страница 200: ...Setup and Installation 200 Optional modules 1 2 Version CND ...

Страница 201: ...Setup and Installation 201 Setup and Installation 1 2 ...

Страница 202: ...Setup and Installation 202 3 4 ...

Страница 203: ...Setup and Installation 203 5 6 ...

Страница 204: ...Setup and Installation 204 7 Opening the system 8 Removing the Motherboard MB ...

Страница 205: ...Setup and Installation 205 9 Lower modules Music EB 200 204 LAN interface and S0 ...

Страница 206: ...Setup and Installation 206 Version CND 10 Master and Satellite Modules ...

Страница 207: ...Setup and Installation 207 Version CND 11 Upper modules CTR UP0 E UP0 E EVM and EB 200 204 ...

Страница 208: ...Setup and Installation 208 Version CND 12 Baby Board VDC module ...

Страница 209: ...Setup and Installation 209 Version CND 13 Connections to the Motherboard MB ...

Страница 210: ...Setup and Installation 210 Version CND ...

Страница 211: ...Setup and Installation 211 14 Connections to the ADSL expansion boards ...

Страница 212: ...Setup and Installation 212 Version CND 15 Connections to the UP0 E module ...

Страница 213: ...Setup and Installation 213 Version CND 16 Connections to the lower EB 200 204 Music modules ...

Страница 214: ...Setup and Installation 214 Version CND 17 Connections to the S0 module ...

Страница 215: ...ta Dimensions Length x Depth x Height 14 17 x 11 33 x 2 53 360 x 288 x 64 4 mm Weight 2 64 lb 1 2 kg Input Voltage Maximum current 220V 60Hz 197mA Supply voltage Maximum current 127V 60Hz 331mA Supply voltage Maximum current 110V 60Hz 381mA ...

Страница 216: ...Setup and Installation 216 HiPath 1150 Package Contents ...

Страница 217: ...Setup and Installation 217 Setup and Installation 1 2 ...

Страница 218: ...Setup and Installation 218 3 Power Supply 4 ...

Страница 219: ...Setup and Installation 219 5 6 View of Module Slots HiPath 1150 Slot 3 Slot 1 Slot 2 Slot 4 Side view of the power supply ...

Страница 220: ...Setup and Installation 220 7 CTR UP0 E Module 8 EVM Module ...

Страница 221: ...Setup and Installation 221 9 Installing expansion and optional modules 10 ...

Страница 222: ...Setup and Installation 222 11 12 Power Supply ...

Страница 223: ...Setup and Installation 223 Example of a configuration 1 EB210 206 Modules only 206 2 EB210 module only 210 3 To install a system telephone use a CD pair and a position of extension A B Battery ...

Страница 224: ...Setup and Installation 224 Installing the ADSL TME1 UP0 E and S0 modules 1 2 ...

Страница 225: ...n boards These can only be installed in slots 3 or 4 in the HiPath 1150 Æ page 219 and in slot 2 in the HiPath 1190 S0 module The S0 module can only be installed in Slot 3 on the HiPath 1150 Æ page 219 and Slots 1 and or 11 on the HiPath 1190 ...

Страница 226: ...odule you must install a CTR UP0 E module on the MB Æ page 219 Warning Do not touch the administration serial interface connector of the TME1 module before disconnecting all analog extensions and external line connectors Failure to follow this procedure may ex pose the user to dangerous voltages The TME1 module intercon necting cables and connectors should only be handled by qualified technical pe...

Страница 227: ... and Installation 227 EVM Module The EVM module is connected to the MB of the systems HiPath 1150 Æ page 219 CTR UP0 E Module The CTR UP0 E module is connected to the MB of the HiPath 1150 systems Æ page 219 ...

Страница 228: ...ade via two wires A1 B1 while the connection to the entrance telephone interface is made via four wires A2 B2 KL1 KL2 Dimensions Length x Depth x Height 18 50 x 14 56 x 2 83 470 x 370 x 72 mm 1150 3 93 100 mm Weight HiPath 1150 8 04 lb 9 36 lb 3 65 kg 4 25 kg Maximum current 1 5 A Supply voltage 110 230 V Full Scale 50 60Hz Battery Type Valve Regulated Lead Acid VRLA Connections Faston connector V...

Страница 229: ...he length of the cables between the X2 connector and the PABX must not exceed 32 8 feet For information on the length of wiring between the X6 connector and the entrance telephone at the street see the manufacturer s specifi cations This interface supports HDL s brand entrance telephones F5AZ F8AZ and F9AZ In Pager Mode the X4 connector is connected to an audio output and the X5 connector to an au...

Страница 230: ... numbers without COS analysis Æ page 31 072 deactivated Assigning a class of service COS Æ page 32 111 77 for all extensions Special class of service for a blocked extension Æ page 34 096 0 for all extensions COS changeover Æ page 36 178 blocked Language Æ page 20 164 3 for all systems Country group of countries Æ page 20 165 01 Brazil Attendant console Æ page 36 150 None Carrier selection mode LC...

Страница 231: ...pe of answering signal Æ page 48 158 deactivated Dial tone detection Æ page 49 160 activated Operation as Satellite PABX External line connection Æ page 50 133 1 For a public exchange Operation as Satellite PABX Second external access code Æ page 50 134 0 False tone Æ page 51 063 deactivated Argenti na Korea and India activated Other coun tries Internal access code for automatic seizure Æ page 51 ...

Страница 232: ...27 None Round robin Distribution of Calls to agents Æ page 60 028 activated Time for agent s Notes Æ page 61 029 00 0 seconds Ring Signal Timeout for agents Æ page 61 030 06 30 seconds Agent status after signaling timeout Æ page 62 176 unavailable Cascaded call forwarding partner Æ page 63 181 0 Last Time in a UCD queue Æ page 64 031 12 1 minute Waiting message before signaling a UCD call Æ page 6...

Страница 233: ...ash detection time Æ page 76 131 035 Portugal Argentina and Thailand 036 Korea 028 Other countries Overflow extension Æ page 77 132 1 no answer none 2 and 3 the first extension on the system Hotline Æ page 78 145 None Warmline Æ page 79 162 0 seconds Assigned group Æ page 80 151 None CD interface assignment Æ page 80 for system telephones 146 HiPath 1120 1150 1st 11 2nd 12 etc HiPath 1190 None Ext...

Страница 234: ...er an analog trunk Æ page 90 082 06 30 seconds Modem extension Æ page 91 085 None MSN and extension assignment for external outgo ing calls Æ page 90 086 None External to external transfer Æ page 91 091 deactivated Elapsed timeout for external to external connection Æ page 92 218 deactivated Configuring a timeout for an external to external connection Æ page 92 219 1 hour Disconnect timeout after ...

Страница 235: ...rom the caller list Æ page 102 171 None Date time manual setting Æ page 103 114 DD MM YY HH MM Automatic update of date time Æ page 104 038 activated Callback for external calls via ISDN Æ page 104 221 activated Call charge unit Æ page 105 195 Slot 0 Factor 00001 Multiplier for call charge factor Æ page 105 042 001 Value 1 Call charge factor for extensions Æ page 106 043 1 Default Call charge valu...

Страница 236: ... Remote software update Æ page 117 9415 Remote operation mode Æ page 117 084 1 Via ISDN Activating remote administration Æ page 117 066 deactivated External number configuration Æ page 118 067 None remote administration password Æ page 118 068 None Remote MSN Æ page 118 069 None Without MSN verification Æ page 120 070 deactivated Remote administration via dtmf Æ page 120 157 activated Ending remot...

Страница 237: ...ion Æ page 135 244 deactivated Data transmission rate Æ page 136 120 3 19200 baud 25 digit suppression in CDR records Æ page 136 121 0 Call detail report for incoming calls Æ page 137 161 1 Outgoing Incoming Call detail report filter Æ page 137 167 None Call detail report through serial interface Æ page 138 006 deactivated Fax DID Æ page 139 Answering menu Æ page 140 009 None Recording a greeting ...

Страница 238: ...a digital line to an MSN Æ page 153 078 All assigned External line prefix Æ page 160 189 None External number registration Æ page 160 191 None Assignment of an MSN to attendants Æ page 161 192 None Busy signal Æ page 163 004 None Local area code filter Æ page 164 011 None Country area code filter Æ page 164 012 55 Brazil Call deflection Æ page 154 229 deactivated ISDN Layer 1 Æ page 155 101 Depend...

Страница 239: ...ne Mailbox password Æ page 171 204 1234 Enabling mailbox recording Æ page 172 205 deactivated Type of greeting for a mailbox Æ page 172 206 1 Mailbox greeting configuration Æ page 173 207 1 Message source Æ page 173 208 None Message mode Æ page 174 209 1 Message for MSN Æ page 174 210 None System number Æ page 174 211 None Type of system number Æ page 175 212 1 Other countries 3 Italy Type of voic...

Страница 240: ...nutes MSN Assignment for the Sensor Æ page 180 051 None Number dialed by sensor activation Æ page 181 052 None Number of attempts for activating the sensor Æ page 181 053 001 1 attempt DTMF signals for the sensor Æ page 182 177 None Sensor message Æ page 182 213 None Relay Æ page 183 175 Switch Timer to deactivate the relay Æ page 184 173 002 1 second External Ring for Activating the Relay Æ page ...

Страница 241: ...ment contains merely general de scriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as the result of further development of the products An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of the contract All trademarks are the property of Siemens Enterprise Communication...

Отзывы: