![Siemens 7SR10 Argus Series Скачать руководство пользователя страница 194](http://html.mh-extra.com/html/siemens/7sr10-argus-series/7sr10-argus-series_manual_383097194.webp)
7SR10 Technical Manual
Chapter 4 - Page 44 of 78
© 2018 Siemens Protection Devices
OBJECT
REQUEST
(Library will parse)
RESPONSE
(Library will respond with)
Object
Number
Variation
Description
Function Codes
(dec)
Qualifier Codes
(hex)
Function
Codes
(dec)
Qualifier Codes
(hex)
20
6
16-Bit Binary Counter
(without Flag)
1 (read)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index)
129
(response)
00, 01 (start-stop)
17, 28 (index
- see note 2)
20
7
32-Bit Delta Counter
(without Flag)
20
8
16-Bit Delta Counter
(without Flag)
21
0
Frozen Counter
- Any Variation
1 (read)
22 (assign class)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index)
21
1
32-Bit Frozen Counter
(with Flag)
1 (read)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index)
129
(response)
00, 01 (start-stop)
17, 28 (index
- see note 2)
21
2
16-Bit Frozen Counter
(with Flag)
1 (read)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index)
129
(response)
00, 01 (start-stop)
17, 28 (index
- see note 2)
21
3
32-Bit Frozen Delta
Counter (with Flag)
21
4
16-Bit Frozen Delta
Counter (with Flag)
21
5
32-Bit Frozen Counter
(without Time Of Freeze)
1 (read)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index)
129
(response)
00, 01 (start-stop)
17, 28 (index
- see note 2)
21
6
16-Bit Frozen Counter
(without Time Of Freeze)
1 (read)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index)
129
(response)
00, 01 (start-stop)
17, 28 (index
- see note 2)
21
7
32-Bit Frozen Delta Counter
(with Time Of Freeze)
21
8
16-Bit Frozen Delta Counter
(with Time Of Freeze)
21
9 (default -
see note 1)
32-Bit Frozen Counter
(without Flag)
1 (read)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index)
129
(response)
00, 01 (start-stop)
17, 28 (index
- see note 2)
21
10
16-Bit Frozen Counter
(without Flag)
1 (read)
00, 01 (start-stop)
06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index)
129
(response)
00, 01 (start-stop)
17, 28 (index
- see note 2)
21
11
32-Bit Frozen Delta Counter
(without Flag)
21
12
16-Bit Frozen Delta Counter
(without Flag)
22
0
Counter Change Event
- Any Variation
1 (read)
06 (no range, or all)
07, 08 (limited qty)
22
1 (default -
see note 1)
32-Bit Counter Change
Event (without Time)
1 (read)
06 (no range, or all)
07, 08 (limited qty)
129
(response)
130
(unsol. resp)
17, 28 (index)
22
2
16-Bit Counter Change
Event (without Time)
1 (read)
06 (no range, or all)
07, 08 (limited qty)
129
(response)
130
(unsol. resp)
17, 28 (index)
22
3
32-Bit Delta Counter
Change Event
(without Time)
22
4
16-Bit Delta Counter
Change Event
(without Time)
22
5
32-Bit Counter Change
Event (with Time)
1 (read)
06 (no range, or all)
07, 08 (limited qty)
129
(response)
130
(unsol. resp)
17, 28 (index)
22
6
16-Bit Counter Change
Event (with Time)
1 (read)
06 (no range, or all)
07, 08 (limited qty)
129
(response)
130
17, 28 (index)
Содержание 7SR10 Argus Series
Страница 1: ...7SR10 Argus Overcurrent Relay Reyrolle Protection Devices ...
Страница 2: ...Siemens Protection Devices Limited 2 ...
Страница 152: ...7SR10 Technical Manual Chapter 4 Page 2 of 78 2018 Siemens Protection Devices ...
Страница 156: ...7SR10 Technical Manual Chapter 4 Page 6 of 78 2018 Siemens Protection Devices ...
Страница 188: ...7SR10 Technical Manual Chapter 4 Page 38 of 78 2018 Siemens Protection Devices ...
Страница 216: ...7SR10 Technical Manual Chapter 4 Page 66 of 78 2018 Siemens Protection Devices ...
Страница 218: ...7SR10 Technical Manual Chapter 4 Page 68 of 78 2018 Siemens Protection Devices ...
Страница 220: ...7SR10 Technical Manual Chapter 4 Page 70 of 78 2018 Siemens Protection Devices ...
Страница 222: ...7SR10 Technical Manual Chapter 4 Page 72 of 78 2018 Siemens Protection Devices ...