Brief description
•
The object is placed on a rugged glass plate. The object does not need to be aligned.
•
In the operating mode with bar code scanning, the object is identified using a wired bar
code scanner. Electronic scales measure the weight of the object.
In the operating mode without bar code scanning, the measuring process starts with
the system detecting a stable weight value. There is no hand-held scanner.
•
To measure the dimensions, a gantry with two pairs of light grids is moved manually
over the object using two linear guides. Measurements can be taken in both directions.
The object’s dimensions and volume are measured.
•
The data are sent to the warehouse management system in a stationary solution via
Ethernet. An external PC or screen is not required. In the mobile variant of the Master
Data Analyzer, the data are sent via a WLAN access point.
•
All system components are pre-assembled in a rugged industrial design and are ready
for operation immediately after commissioning.
The majority of the images and screenshots in these operating instructions visualize the
Master Data Analyzer in the operating mode with bar code scanning.
2.3
Intended use
The Master Data Analyzer may only be used as described in
It may only be used by qualified personnel in the environment in which it was
mounted and initially commissioned by qualified safety personnel in accordance with
these operating instructions.
The equipment may only be operated in an industrial environment. Operation of the
system is not allowed outdoors or in an explosion-protected environment.
If used in any other way or if alterations are made to the system or the devices are
opened – including in the context of mounting and installation – this will void any warranty
claims directed to SICK AG.
Examples of non-intended use:
•
Measurement of products not defined in the contract or in these operating instructions.
•
Non-observance of the permitted parameters for measuring objects.
•
Failure to observe the operating instructions.
•
Use of parts other than original spare parts.
WARNING
Danger due to improper use
Non-intended use of the device can lead to danger to the life and limb of persons and
damage to the plant.
The device must only be used for the intended use.