SAFETY
2
9
8020065-ZLP4/2017-08-10|SICK
Subject to change without notice
O P E R A T I N G I N S T R U C T I O N S | Master Data Analyzer
2
Safety
This chapter concerns your own safety and the safety of the system operator.
▸
Please read this chapter carefully before you begin working with the Master Data
Analyzer.
2.1
Qualified safety personnel
The Master Data Analyzer must only be set up, commissioned, operated, and maintained
by adequately qualified personnel.
The following qualifications are necessary for the various tasks:
Tasks
Qualification
Mounting and maintenance
Practical technical training
Knowledge of the current safety regulations in the workplace
Electrical installation and
device replacement
Practical electrical training
Knowledge of current electrical safety regulations
Commissioning, operation,
and configuration
Basic knowledge of data transmission
Basic knowledge of the design and setup (addressing)
of Ethernet connections when connecting the system to
the Ethernet
Basic knowledge of how to use an HTML browser
(e.g., Internet Explorer) to access the online help
Basic knowledge of 1D/2D code technology
Basic knowledge of the Windows operating system used
Tab. 2: Qualified safety personnel
2.2
Applications of the system
The Master Data Analyzer is a stationary DWS system (
D
imensioning-
W
eighing-
S
canning).
It enables master data for products to be logged in a standardized manner for goods entry
or shipping. The products are measured, weighed, identified, and visualized in a single
operation. Data are processed in real time, regardless of their shape, surface, and
material properties.
Operating modes
The Master Data Analyzer is set up at the factory to support two
operating modes
:
•
Operating mode with bar code scanning
: The object is identified using its bar code
and is then measured. In this case, the Master Data Analyzer supplies the complete set
of master data with bar code, weight, and dimensions.
•
Operating mode without bar code scanning
. This variant assumes that the bar code
for the object is already available, meaning that only the weights and dimensions have
to be logged. The measurement results are assigned to an existing bar code in the
customer’s system.