OPERATION
8020065-ZSP4/2017-08-10|SICK
O P E R A T I N G I N S T R U C T I O N S | Master Data Analyzer
Subject to change without notice
90
Repeating measurements
The bar code must be scanned again before the measurement can be repeated. This
creates a new measurement data set.
1. Confirm the error message with
OK
and scan the bar code with the hand-held scanner
or enter it manually.
You can also record the bar code directly. The window containing the error message
closes automatically.
2. Move the measurement gantry over the object.
Once the volume has been measured, all measured values appear on the display and
are transmitted by the MSC800 controller to the customer system via the defined
interface.
7.6.3
Volume measurement without a stable weight (only for operating mode without bar code scanning)
In the operating mode without bar code scanning, the following error message appears
if you have placed an object on the measurement field and performed the volume
measurement too early. Too early means before the system has been able to detect a
stable weight.
Repeating measurements
The error message disappears automatically as soon as a stable weight has been
detected.
Before the repeat measurement, the object does not need to be removed from the glass
panel and repositioned. You can start with the repeat measurement straight away. A new
measurement data set does not need to be created.
1. If the measurement gantry is already located over the object, move it back to the start
or end position.
2. Perform the volume measurement.
Once the volume has been measured, all measured values appear on the display and
are transmitted by the MSC800 controller to the customer system via the defined
interface.
Note