COMMISSIONING
6
59
8020065-ZLP4/2017-08-10|SICK
Subject to change without notice
O P E R A T I N G I N S T R U C T I O N S | Master Data Analyzer
6.3.4
Setting the controller to online
Establish a connection between the SOPAS project and the controller. This connection will
make it possible to subsequently read controller parameters and configuration data in the
SOPAS project or write these to the controller from SOPAS.
During the initial commissioning, the standard parameters saved on the controller at the
factory are transferred to the SOPAS project and then adapted to the requirements of the
relevant application there.
Fig. 39: Loading standard parameters into the SOPAS project
1. Click the
Offline
button in the tile.
2. You are prompted to synchronize the controller’s device data with the device data of
the SOPAS project.
3. As the standard parameters are currently only available in the controller and are not
yet in the SOPAS project, click the
Read parameters
option.
The connection between the controller and the configuration PC is now established.
The standard parameters are transferred from the controller into the SOPAS project.
Online
appears in the tile. The LED lights up green.