Teach function
Time
[ms]
Explanation in chap.
Switching window for Q
2
: Teach Q near
1300
Window for Q
2
: Teach Q far
1400
ObSB (Background) for Q
2
: Teach Q
1500
ObSB (Background) for Q
2
: Teach Q not
1600
Switching window for Q
2
: Centering
teach
1
1700
see "Centering function or center displace‐
ment", page 67
Q
A
with 4-20 mA for Q
2
: Teach 4 mA
1800
Q
A
with 4-20 mA for Q
2
: Teach 20 mA
1900
Q
A
with 0-10 V for Q
2
: Teach 0 V
2000
Q
A
with 0-10 V for Q
2
: Teach 10 V
2100
Q
A
(4-20 mA or 0-10 V): Centering teach
1
2200
see "Centering function or center displace‐
ment", page 67
Switch off the MF confirmation
2300
see "Confirmation of the teach via MF via
output Q
Switch on the MF confirmation
2400
see "Confirmation of the teach via MF via
output Q
Signal level warning (SLW) Q
1
: Teach Q
2500
see "Operating examples via display: “Q
SLWarning” switching mode", page 47
Signal level warning (SLW) Q
1
: Teach Q
not
2600
see "Operating examples via display: “Q
SLWarning” switching mode", page 47
Signal level warning (SLW) Q
2
: Teach Q
2700
see "Operating examples via display: “Q
SLWarning” switching mode", page 47
Signal level warning (SLW) Q
2
: Teach Q
not
2800
Reset Wi-Fi settings to factory condition
2
3800
Laser off
> 5000
see "Switch the laser on/off", page 69
1
Centering limits. The near and far points that have been moved via centering must always lie within the
value range limits. Moved points must always be evaluated by the user.
2
Can be used only in variants with a Wi-Fi interface. Function available only in the first 60 seconds after
switching on the device.
6.4.5.3
Confirmation of the teach via MF via output Q
1
(“Confirm teach”)
Description
With this function, a confirmation can be output via the switching output Q
1
for each
teach via multifunctional input.
6
OPERATION
60
O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro
8017154/1AVV/2021-03-24 | SICK
Subject to change without notice