6.4.5.3.1
Operating example via display: Confirm teach
Confirmation of the teach via MF (“Confirm teach”)
Operating example or steps:
RUN mode
→ Q
1
Output
/
to → MF Input
→ MF Function
/
to → Confirm Teach
→ No
/
to → Yes
→ Saved
to → RUN mode
Necessary default settings:
User level = Advanced
MF Function = Teach
Factory setting:
No
6.4.6
Speed setting (“Speed”)
Description
The DT50-2 Pro distance sensor provides the option of setting various speeds.
The Easy user level has five predefined speed settings: Super fast, Fast, Medium
(factory setting), Slow and Super Slow; the Advanced user level additionally has the
configurable Expert mode.
Table 9: Speed settings for the sensor
Easy user level
Super
-fast
-
Fast
Medi
um
-
Slow
Super
-slow
-
-
Advanced user level
0
1
2
3
4
5
6
7
8
Integration time
1
/ out‐
put time (laser class 2)
[ms]
0.33
0.67
1.33
3.33
6.67
10.0
30.0
74.0
160.0
Integration time
1
/ out‐
put time (laser class 1)
[ms]
0.67
1.33
2.67
6.67
13.33 20.0
60.0
148.0 320.0
Integration depth [meas‐
uring cycles]
1
2
4
10
20
30
90
222
480
Response time
2
/ ana‐
log output (laser class 2)
[ms]
0.83
1.67
3.33
8.33
16.67 25.0
75.0
185.0 400.0
Response time
2
/ ana‐
log output (laser class 1)
[ms]
1.67
3.33
6.67
16.67 33.33 50
150
370
800
Switching frequency
2
switching output (laser
class 2) [Hz]
1000.
0
500.0 250.0 100.0 50.0
33.33 11.11 4.50
2.08
Switching frequency
2
switching output (laser
class 1) [Hz]
500
250
125
50
25
16.67 5.5
2.25
1
1
Continuous change of the distance from the object in the measuring range
2
Lateral entry of the object into the measuring range
The selected speed setting affects the performance of the device. The appendix shows
the “repeatability” and “distance” performance data as a function of the remission
values 6%, 18% and 90% for the five predefined speed settings,
6
OPERATION
62
O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro
8017154/1AVV/2021-03-24 | SICK
Subject to change without notice