Teach in the length of the reference object
Operating example or steps:
RUN mode
→ Q
1
Output
/
to → Q
2
Output
→ Function Q
2
/Q
a
/
to → Teach Q
a
→ Length Ref. Object
→ ESC?
Move the object past the sensor
After reference object
→ Saved
to → RUN mode
Necessary default settings:
User level = Advanced
Function Q
2
/Q
a
= 4-20 mA or 0-10 V
ModeQ
a
= Shape
Factory setting:
-
Teaching in the reference object shape
Operating example or steps:
RUN mode
→ Q
1
Output
/
to → Q
2
Output
→ Function Q
2
/Q
a
/
to → Teach Q
a
→ Length Ref. Object
/
to → Shape of ref. object
→ ...
Move the object past the sensor
After the object is automatically saved
to → RUN mode
Necessary default settings:
User level = Advanced
Function Q
2
/Q
a
= 4-20 mA or 0-10 V
ModeQ
a
= Shape
Length Ref. Object = defined
Factory setting:
-
Manually set the shape trigger threshold for Q
a
Operating example or steps:
RUN mode
→ Q
1
Output
/
to → Q
2
Output
→ Function Q
2
/Q
a
/
to → Manual Q
a
→ Length Ref. Object
/
to → Self Trigger
→
0
00025 (Note:
0
= flashing 0)
/
,
/
,
/
,
/
,
/
,
/
to → desired shape trigger
threshold
→ Saved
to → RUN mode
Necessary default settings:
User level = Advanced
Function Q
2
/Q
a
= 4-20 mA or 0-10 V
ModeQ
a
= Shape
Factory setting:
-
6.4.5
Multifunctional input (“MF Input”)
Description
The multifunctional input (MF, at pin 5) is for
OPERATION
6
8017154/1AVV/2021-03-24 | SICK
O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro
57