![SICK DT50-2 Pro Скачать руководство пользователя страница 92](http://html1.mh-extra.com/html/sick/dt50-2-pro/dt50-2-pro_operating-instructions-manual_1263899092.webp)
Display
SOPAS ET / SOPASair
IO-Link / IODD
Index
dec
(hex)
Sub
index
Value Text
→
Shape Ref.
Object
1
Teach shape
-
-
-
-
→
Self trigger
1
Shape trigger threshold 111
(0x6F)
-
-
Shape trigger thresh‐
old
→
Q
1
Tolerance
1
Shape Tolerance Q
1
113
(0x71)
-
-
Shape tolerance Q
1
→
Q
1
SLWarning
1
SLW switching point
(signal level warning)
93
(0x5D)
1
(0x01)
-
SLW1 (signal level
warning 1) = Q
1
threshold
1
Advanced user level
11.4.3
Q
2
Output
Display
SOPAS ET / SOPASair
IO-Link / IODD
Index
dec
(hex)
Sub
index
Value Text
Q
2
Output
Settings Q
2
(Output Q
2
) 63
(0x3F)
-
-
Switchpoint 2 settings
Function Q
2
/Q
a
Q
2
/Q
a
output function
121
(0x79)
-
-
Q
2
Output function
→
4-20 mA
4 mA ... 20 mA
121
(0x79)
-
1
4 mA ... 20 mA
→
0-10 V
0 V ... 10 V
121
(0x79)
-
2
0 V ... 10 V
→
Switching
Switching
121
(0x79)
-
3
Switching
→
Q
2
=Q
1
not
not Q
1
121
(0x79)
-
4
not Q
1
→
Off
1
Off
121
(0x79)
-
0
Off
1
Advanced user level
Mode Q
2
Display
SOPAS ET / SOPASair
IO-Link / IODD
Index
dec
(hex)
Sub
index
Value Text
ModeQ
2
Q
2
switching function
63
(0x3F)
2
(0x02)
-
Q
2
switching function
→
DtO (1point)
DtO mode
63
(0x3F)
2
(0x02)
1
Distance to object
(DtO) – 1point
→
Window
Window mode
63
(0x3F)
2
(0x02)
2
Window
→
ObSB (Back‐
ground)
ObSB mode
63
(0x3F)
2
(0x02)
128
Background (ObSB)
→
Shape
1
Shape
63
(0x3F)
2
(0x02)
129
Shape comparison
11
APPENDIX
92
O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro
8017154/1AVV/2021-03-24 | SICK
Subject to change without notice