![SICK DT50-2 Pro Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/sick/dt50-2-pro/dt50-2-pro_operating-instructions-manual_1263899031.webp)
Activate the “Switching window” (“Window”) switching mode for Q
2
Operating example or steps:
RUN mode
→ Q
1
Output
/
to → Q
2
Output
→ Function Q
2
/Q
a
/
to → ModeQ
2
→ DtO (1point)
/
to → Window
→ Saved
to → RUN mode
Necessary default settings:
Function Q
2
/Q
a
= Switching
Factory setting:
-
Teach in the current distance for “Q
2
near” teach methodin the menu
Operating example or steps:
RUN mode
→ Q
1
Output
/
to → Q
2
Output
→ Function Q
2
/Q
a
/
to → Teach Q
2
→ Q
2
near
Position object
→ Saved
to → RUN mode
Necessary default settings:
Function Q
2
/Q
a
= Switching
Mode Q
2
= Window
Factory setting:
-
Manually set the desired distance for “Q
2
near”
Operating example or steps:
RUN mode
→ Q
1
Output
/
to → Q
2
Output
→ Function Q
2
/Q
a
/
to → Manual Q
2
→ Q
2
near
→
0
0200 (Note:
0
= flashing 0)
/
,
/
,
/
,
/
,
/
→ desired distance in mm
→ Saved
to → RUN mode
Necessary default settings:
Function Q
2
/Q
a
= Switching
Mode Q
2
= Window
Factory setting:
-
6.4.1.3
“Object between sensor and background” (ObSB) switching mode
6.4.1.3.1
Description
Output of a switching signal if the reference background is not detected (High Active)
or is detected (Low Active). The “ObSB” or background mode provides for reliable
detection of all objects deviating from the background, regardless of whether these are
highly reflective or jet black.
OPERATION
6
8017154/1AVV/2021-03-24 | SICK
O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro
31