![SICK DT50-2 Pro Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/sick/dt50-2-pro/dt50-2-pro_operating-instructions-manual_1263899047.webp)
6.4.1.6.4
Operating examples via display: “Q
1
SLWarning” switching mode
Select and activate the “Advanced” user level
Operating example or steps:
RUN mode
→ Q
1
Output
/
to → Device
→ User level
→ Easy
/
to → Advanced
→ Saved
to → RUN mode
Necessary default settings:
-
Factory setting:
Easy
Select and activate the “SLWarning” switching mode for Q
1
Operating example or steps:
RUN mode
→ Q
1
Output
→ ModeQ
1
→ DtO (1point)
/
to → SLWarning
→ Saved
to → RUN mode
Necessary default settings:
User level = Advanced
Factory setting:
DtO (1point)
Teach in the current signal level as the switching point or level warning threshold for the signal
level warning via Q
1
as a switching point or level warning threshold
Operating example or steps:
RUN mode
→ Q
1
Output
→ ModeQ
1
/
to → Teach Q
1
→ SLWarning
Position the reference object
→ Saved
to → RUN mode
Necessary default settings:
User level = Advanced
Mode Q
1
= SLWarning
Factory setting:
-
Manually configure the desired signal level in the menu via Q
1
as a switching point or level
warning threshold
Operating example or steps:
RUN mode
→ Q
1
Output
→ ModeQ
1
/
to → Manual Q
1
→ Q
1
SLWarning
→
0
000 (Note:
0
= flashing 0)
/
,
/
,
/
,
/
,
/
to the→ desired level warning threshold
→ Saved
to → RUN mode
Necessary default settings:
User level = Advanced
Mode Q
1
= SLWarning
Factory setting:
-
OPERATION
6
8017154/1AVV/2021-03-24 | SICK
O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro
47