For the output function Q
2
configure and activate /Q
a
through switching
Operating example or steps:
RUN mode
→ Q
1
Output
/
to → Q
2
Output
→ Function Q
2
/Q
a
→ 4 - 20 mA
/
to → Switching
→ Saved
to → RUN mode
Necessary default settings:
-
Factory setting:
4 - 20 mA
Select and activate the ObSB (Background) switching mode for Q
2
Operating example or steps:
RUN mode
→ Q
1
Output
/
to → Q
2
Output
→ Function Q
2
/Q
a
/
to → ModeQ
2
→ DtO (1point)
/
to → ObSB (Background)
→ Saved
to → RUN mode
Necessary default settings:
Function Q
2
/Q
a
= Switching
Factory setting:
-
Teach in the current distance as a reference background for ObSB mode for Q
2
in the menu
Operating example or steps:
RUN mode
→ Q
1
Output
/
to → Q
2
Output
→ Function Q
2
/Q
a
/
to → Teach Q
2
→ Q
2
Align the sensor with the reference background
→ Saved
to → RUN mode
Necessary default settings:
Function Q
2
/Q
a
= Switching
Mode Q
2
= ObSB (Background)
Factory setting:
-
OPERATION
6
8017154/1AVV/2021-03-24 | SICK
O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro
35
Subject to change without notice