10.0
0
Min.
Max. distance
V
2
1
Figure 24: 0-10 V output function in distance mode with rising output behavior
1
Taught-in or manually set distance for 0 V
2
Taught-in or manually set distance for 10 V
20.5
20.0
4.0
3.5
Min.
Max. distance
mA
2
1
Figure 25: 4-20 mA output function in distance mode with falling output behavior
1
Taught-in or manually set distance for 4 mA
2
Taught-in or manually set distance for 20 mA
10.0
0
Min.
Max. distance
V
1
2
Figure 26: 0-10 V output function in distance mode with falling output behavior
1
Taught-in or manually set distance for 0 V
2
Taught-in or manually set distance for 10 V
If an analog output function is selected in combination with distance mode, then the
required settings can be either taught in or manually set. These are described in the
following.
NOTE
If the sensor is unable to measure (e.g. the object is in a blind spot of the sensor,
or there is too little remission or light reflection), a signal is output in the “Distance”
analog mode, which corresponds to the expected behavior with the maximum distance,
see "Behavior if no measurement is possible (NoMeasurement)", page 65
.
6
OPERATION
50
O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro
8017154/1AVV/2021-03-24 | SICK
Subject to change without notice