Carry out a good teach-in for Q
1
Operating example or steps:
RUN mode
→ Q
1
Output
→ ModeQ
1
/
to → Teach Q
1
→ Length of ref. object
/
to → Q
1
Good teach-in
→
ESC?
Move one or more good objects past the sensor
After the last good object
→ Saved
to → RUN mode
Necessary default settings:
User level = Advanced
Mode Q
1
= Shape
Length of ref. object taught in or con‐
figured
Shape of ref. object taught in
Factory setting:
-
Set the switching threshold for the shape comparison for Q
1
manually
Operating example or steps:
RUN mode
→ Q
1
Output
→ ModeQ
1
/
to → Manual Q
1
→ Q
1
Logic
/
to → Q
1
Tolerance
→
1
00 (Note:
1
= flashing 1)
/
,
/
,
/
to the → desired
switching threshold
→ Saved
to → RUN mode
Necessary default settings:
User level = Advanced
Mode Q
1
= Shape
Length of ref. object taught in or con‐
figured
Shape of ref. object taught in
Factory setting:
-
Set the shape of the trigger threshold for Q
1
manually
Operating example or steps:
RUN mode
→ Q
1
Output
→ ModeQ
1
/
to → Manual Q
1
→ Q
1
Logic
/
to → Q
1
Self trigger
→
0
0025 (Note:
0
= flashing 0)
/
,
/
,
/
,
/
,
/
,
/
to → desired shape trigger
threshold
→ Saved
to → RUN mode
Necessary default settings:
User level = Advanced
Mode Q
1
= Shape
Factory setting:
-
OPERATION
6
8017154/1AVV/2021-03-24 | SICK
O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro
41