6.4.1.4.4
Operating examples via display: “Shape comparison” (“Shape”) switching mode
Select and activate the “Advanced” user level
Operating example or steps:
RUN mode
→ Q
1
Output
/
to → Device
→ User level
→ Easy
/
to → Advanced
→ Saved
to → RUN mode
Necessary default settings:
-
Factory setting:
Easy
Select the “Shape” switching mode for Q
1
Operating example or steps:
RUN mode
→ Q
1
Output
→ ModeQ
1
→ DtO (1point)
/
to → Shape
→ Saved
to → RUN mode
Necessary default settings:
User level = Advanced
Factory setting:
DtO (1point)
Teach in the length of the reference object
Operating example or steps:
RUN mode
→ Q
1
Output
→ ModeQ
1
/
to → Teach Q
1
→ Length of ref. object
→
ESC?
Move the object past the sensor
After reference object
→ Saved
to → RUN mode
Necessary default settings:
User level = Advanced
Mode Q
1
= Shape
Factory setting:
-
Teaching in the reference object shape
Operating example or steps:
RUN mode
→ Q
1
Output
→ ModeQ
1
/
to → Teach Q
1
→ Length of ref. object
/
to → Shape of ref. object
→ ...
Move the object past the sensor
After the object is automatically saved
to → RUN mode
Necessary default settings:
User level = Advanced
Mode Q
1
= Shape
Length of ref. object taught in or con‐
figured
Factory setting:
-
6
OPERATION
40
O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro
8017154/1AVV/2021-03-24 | SICK
Subject to change without notice