6.4.1.2.4
Operating examples via display: “Switching window” (“Window”) switching mode
Activate the “Switching window” (“Window”) switching mode for Q
1
Operating example or steps:
RUN mode
→ Q
1
Output
→ ModeQ
1
→ DtO (1point)
/
to → Window
→ Saved
to → RUN mode
Necessary default settings:
-
Factory setting:
DtO (1point)
Teach in the current distance for “Q
1
near” in the menu
Operating example or steps:
RUN mode
→ Q
1
Output
→ ModeQ
1
/
to → Teach Q
1
→ Q
1
near
Position object
→ Saved
to → RUN mode
Necessary default settings:
Mode Q
1
= Window
Factory setting:
-
Teach in the current distance for “Q
1
far” in the menu
Operating example or steps:
RUN mode
→ Q
1
Output
→ ModeQ
1
/
to → Teach Q
1
→ Q
1
near
/
to → Q
1
far
Position object
→ Saved
to → RUN mode
Necessary default settings:
Mode Q
1
= Window
Factory setting:
-
Manually set the desired distance for “Q
1
near”
Operating example or steps:
RUN mode
→ Q
1
Output
→ ModeQ
1
/
to → Manual Q
1
→ Q
1
near
→
0
0200 (Note:
0
= flashing 0)
/
,
/
,
/
,
/
,
/
→ desired distance in mm
→ Saved
to → RUN mode
Necessary default settings:
Mode Q
1
= Window
Factory setting:
-