6.4.7.5.1
Operating example via display: Behavior if no measurement is possible (NoMeasurement)
Select behavior if no measurement is possible (NoMeasurement)
Operating example or steps:
RUN mode
→ Q
1
Output
/
to → Device
→ User level
/
to → NoMeasurement
→ Clamp
/
until → the desired behavior is carried out if no
measurement is possible
→ Saved
to → RUN mode
Necessary default settings:
User level = Advanced
Factory setting:
Clamp
6.4.8
Read out sensor information
It is possible read out various status information from the sensor.
Table 11: Sensor status information
Display
Wi-Fi (app)
SOPAS
IO-Link
Hardware version
Info > HW Ver
--
“Identification”
page
Index 22 (0x16)
“Hardware Version”
Software version
Info > FW Ver
--
“Diagnostics”
page
Index 23 (0x17) “Soft‐
ware Version”
Error memory
2
Info > Status
1
--
“Diagnostics”
page
Index 89 (0x59) Error
Status
Temperature
3
-
--
“Diagnostics”
page
Index 153 (0x99)
“Temperature”
Operating hour
counter
Info > Operat
1
--
“Diagnostics”
page
Index 90 (0x5A)
“Device Operating
Time”
1
Only available in the “Advanced” user level
2
For more information, visit
see "Detecting and displaying errors", page 74
3
Related information
6.4.9
Other functions
Additional functions are described in this chapter. Most of these functions cannot be
accessed via the display. The operating options used to access these functions are
included in their respective descriptions.
6.4.9.1
Centering function or center displacement
The centering function can be used to shift the center of the switching range or analog
range (12 mA/5 V) to a new position.
This new position can be taught in or input as a numerical value.
The centering function is available for the outputs Q
1
and Q
2
in “Window” mode and for
the Q
a
(analog) output.
The previous distance between both points (close and distant) is maintained. The close
and distant values must not be moved beyond the sensor limits during the centering
process. Otherwise, the value shift is rejected.
OPERATION
6
8017154/1AVV/2021-03-24 | SICK
O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro
67