8
Troubleshooting
Possible faults and rectification measures are described in the table below. In case
of faults that cannot be rectified using the information below, please contact the
manufacturer. See the back page for your agency.
General faults, warnings and errors
General faults are subdivided into warnings and errors. Current measured values con‐
tinue being output when there are warnings; measurement is no longer possible when
there are faults. Warnings and errors are signaled by the
Status
LED. The
Power
LED
signals that the sensor is connected to the power supply.
8.1
Detecting and displaying errors
In addition to measurement errors (
see "Behavior if no measurement is possible
), the sensor can also detect and display other errors.
These are output by the display, Sopas ET or IO-Link.
Error memory
The sensor has an error memory where internal error states of the sensor are recorded.
The last error to have occurred is always saved. The contents of the error memory
are retained when the sensor is switched off and when the “Restore Factory Settings”
function is used.
Possible errors
Table 16: Explanation of the error code
Error code
Meaning
Countermeasure(s)
OK
No error
--
ERR010
Operating temperature under‐
shot
Check the ambient tempera‐
ture and raise it, if necessary
WRN011, ERR011
Operating temperature
exceeded
Check the ambient tempera‐
ture and lower it, if necessary
WRN045, WRN046, ERR045,
ERR046
Electrical fault
Check the electrical environ‐
ment and improve it, if neces‐
sary (stability, power supply,
EMC influences)
If a different message is output, please contact the manufacturer's technical support.
8.1.1
Operating example via display: Display device status (“Status”)
Display device status (“Status”)
Operating example or steps:
RUN mode
→ Q
1
Output
/
to → Info
→ FW Version
/
to → Status
→ Status is displayed
to → RUN mode
Necessary default settings:
User level = Advanced
Factory setting:
OK
8
TROUBLESHOOTING
74
O P E R A T I N G I N S T R U C T I O N S | DT50-2 Pro
8017154/1AVV/2021-03-24 | SICK
Subject to change without notice