Operating Instructions
Chapter
9
DME5000
8009813/ZJV1/2017-05
© SICK AG • Germany • Subject to change without notice
113
Technical Data
9.4
Technical Data DME5000-2xx
DME5000-
211
212
213
214
215
217
Part no.
1024081
1024082
1025250
025834
1025835
1028245
Measuring range
0.15 … 150 m
Accuracy
± 3 mm
Repeatability
1 mm
Measured value output
1 ms
2 ms
2 ms
2 ms
2 ms
2 ms
Resolution data interface (adjustable)
0.05 … 5 mm
1/32 … 1/2 mm
Resolution sin/cos (adjustable)
0.25 … 4 mm
Temperature drift (typ.)
0.1 mm/K
Temperature influence
1 ppm/K
Air pressure influence
0.3 ppm/hPa
Initialization time
Type. 1.5 s
900 ms
Max. movement speed
10 m/s
Supply voltage U
V
2)
DC 18 … 30 V
Residual ripple
5 V
SS
Power intake (without heating)
< 250 mA at DC 24 V
Light source
Laser diode (red light)
Laser class
2 (EN 60825-1/C.D.R.H.)
Service life (at 25 °C)
MTTF 50.000 h
Light spot diameter/distance
max. 270 mm/150 m
Switching outputs MF1, MF2
B (push/pull)
Output (MF1/MF2)
HIGH: U
V
‒ (
< 3 V); LOW < 2 V
Input (MF1)
4)
HIGH: > 12 V; LOW < 3 V
Output current
100 mA (short-circuit proof, overload proof)
Interfaces
SSI
PROFIBUS
®
12 MBd
RS-422
DeviceNet 500 kBd
Hiperface
Operating ambience temperature
–
10 … +55
°C
Storage temperature
–
25 … +75
°C
Heating DME5000
221
222
223
224
Not
available
227
Part no.
1024085
1024086
1025251
1025837
1028246
Operating ambience temperature
–
40 … +55
°C
Power intake (with heating)
< 1,000 mA at DC 24 V
Protection type
IP 65
Electrical protection class
VDE class 2 (rated voltage 32 V)
EMC
EN 61000-6-2, EN 55011: Class B
Mechanic load
Shock: EN 600 68-2-27/-2-29; Sine: EN 600 68-2-6; Noise: EN 600 68-2-64
Weight
approx. 1650 g
1)
Statistic error 1
σ
, ambience conditions consistent at minimum activation time: 10 min
2)
Protected against polarity reversal
3)
U
V
tolerances must not be exceeded or undercut
4)
Not protected against polarity reversal
5)
Max. 100 nF/20 mH