Chapter
7
Operating Instructions
DME5000
96
© SICK AG • Germany • Subject to change without notice
8009813/ZJV1/2017-05
Menu Structure
Service
Collective output for freely adjustable status messages in "OR" links that enable
conclusions about the device condition.
Active
Inactive
Laser
On
(default)
Pre-failure message
Laser diode
Pre-failure message
Laser diode
Off
–
Level
On
(default)
Pre-failure message
Contamination
Not contaminated
Off
–
UpperTemp
On
(default)
Overtemperature
monitoring:
Internal device
temperature > upper set
temperature limit
Internal device
temperature < upper
set temperature limit
Off
–
LowerTemp
On
(default)
Undertemperature
monitoring:
Internal device
temperature < lower set
temperature limit
Internal device
temperature > lower
set temperature limit
Off
–
Plausib(ility)
On
(default)
Defective measured
value, measured value
output "0", causes:
– Light beam interruption
– Contamination
– Optical/electrical
interferences
Measured value OK
Off
–
Ready
On
(default)
Initialization
Hardware error,
Measuring error,
Laser off
Ready,
Measured value OK
Off
–
Bus Status
On
Bus error
SSI: no clock signal
PB/DN: no telegram
transfer
RS-422/Hiperface: –
Data transfer OK
RS-422/Hiperface:
independent of bus
status
Off
(default)
–