Operation
Status displays
Display
Meaning
Is displayed
Is not displayed
MF1
Multifunctional
in-/output
In-/output active
In-/output not active
MF2
Multifunctional output
Output active
Output not active
TMP
Device inside
temperature
Pre-failure message:
Internal device
temperature has
reached threshold
range
Internal device
temperature OK
ATT
Contamination
Pre-failure message:
Reception level within
the threshold range
Reception level OK
LSR
Laser
Pre-failure measuring
laser
Laser OK
PLB
Plausibility
Measuring error
Cause: e.g. light beam
interruption,
contamination,
optical/electrical
interferences
Measured value OK
RDY
Ready
When ready for
operation
Initializing, hardware
defect
BUS
Interface:
SSI
PROFIBUS
®
DeviceNet
RS-422
Hiperface
Clock signal received
Telegram transfer
Telegram transfer
Continuous mode
‒
No clock signal
No telegram transfer
No telegram transfer
Request mode
Independent of bus
status
For removal measures in error messages/pre-failure messages, see chapter 11
"Troubleshooting".