Operating Instructions
Chapter
7
DME5000
8009813/ZJV1/2017-05
© SICK AG • Germany • Subject to change without notice
93
Menu Structure
MF1
Parameterizable output or input
Act.State
Parameterization of switching logic for MF1 = output
Active 1 (default)
HIGH-level at active output (closer/NO)
Active 0
LOW-level at active output (opener/NC)
Parameterization of switching logic for MF1 = input
Active 1 (default)
Activation of input with rising flank
Active 0
Activation of input with dropping flank
Function
Distance
(default)
MF1 is used as distance switching output,
see 3.3.3.
Service
MF1 is used as service output, see 3.3.4.
Sleep mode
MF1 is used for activation of sleep mode (laser off),
confirmation by ready status
Function description see section 13.5 "Sleep Mode".
Preset
MF1 is used as input for activation of the preset
(overwriting the offset).
Offset = Preset value - current measured value
For function description, see section 13.1 "Preset".
SPEED
MF1 is used as speed switching output, see 3.3.5.
Monitor
(for SSI or Hiperface version only): Displayed if monitor
interface is set to ON in 3.1.4 or 3.1.5.
Distance
MF1 is used as distance switching output.
Active when "UpperLimit" is exceeded.
Inactive when below "LowerLimit".