13.2.2
Data Format Master to DME
(DDLM_Data_Exchange)
Active (1)
Inactive (0)
Encoder profile
Bit 31
Preset version
Bit 30 ... 0
Preset value Unit according to resolution. Value range
+/
–250 m
SICK profile
Active (1)
Inactive (0)
Bit 31
Preset version
Bit 30
Not assigned
Not assigned
Bit 29
Laser off
Laser on
Bit 25 ... 28 Not assigned
Not assigned
Bit 24 ... 0
Preset value´ Unit according to resolution.
Value range +/
–250 m
13.2.3
Diagnosis Data (for Activated Parameter "Extended Diagnostics")
(DDLM_Slave_Diag)
Encoder profile
Diagnosis
Class 1
Octet 1 ... 16
Octet 7 ... 16
Class 2
Octet 1 ... 63
Octet 7 ... 63
Octet
Active (1)
Inactive (0)
Octet 1 … 6
DP standard diagnosis
Octet 7
Diagnostic Header
Octet 8
Alarms
Bit 0
Measuring error
Bit 3
Pre-failure message
Bit 4
Device error
Bit 1, 2, 5,
6, 7
Not assigned
Octet 9
Operating Status
Bit 1
Class 2
Class 1
Bit 6
Extended Diagnostics
Normal Diagnostics
Bit 7
Preset-Mode: Parameter
offset is ignored
Parameter offset is
accepted
Bit 0, 2, 3,
4, 5
Not assigned
Octet 10
Encoder Type 7
Octet 11 … 14
Measuring step (linear)
Octet 15 … 16
Not assigned