3
SYSTEM DESCRIPTION
46
8020776/12AX / 2019-05-31|SICK
O P E R A T I N G I N S T R U C T I O N S | Free Flow Profiler
Subject to change without notice
The following figure shows the combination of the vertical and horizontal distance for the
LMS Axle that generates the best measurement results.
Fig. 41: AxleDetector project planning – Ideal mounting position for the LMS Axle
The chart can be interpreted as follows:
•
The dark green triangle (1) marks the area where the LMS Axle will achieve the best
possible performance.
•
A mounting position within the light green triangle (2) will provide good to very good
results.
•
If the LMS Axle is mounted within the gray area (3), the system's ability to count axles
accurately will be reduced.
Requirements for the mounting position and rotation
The laser scanner that is mounted at the side of the lane must be in the
same measuring
plane
as the LMS Width.
Fig. 42: AxleDetector project planning – Distance of the LMS Axle (on the Z-axis)
Position