Welding Cable Selection
Use welding cables with a cross-sectional area that is larger than the proper
cross-sectional areas indicated in the table below.
Using cable that is less than the proper cross-sectional area reduces the weld
output.
<<<<
Note
>>>>
•
Use welding cables when they are completely extended (not coiled). Using a cable
that is coiled reduces the weld output.
Proper Cable Cross-Sectional Area
(
Units
:
mm
2
)
Return Length
Weld Current
20m
30m
40m
60m
80m
100m
400A
38
50
60
100
125
200
350A
30
50
60
80
125
150
300A
30
38
50
80
100
125
250A
22
30
38
60
80
100
200A
22
30
30
50
60
80
150A
22
22
22
38
50
60
100A
22
22
22
30
30
38
8-2
.
.
.
.
Welding Polarity
There are "
+
" (positive) and "
-
" (negative) weld output terminals.
Refer to the table below to select a polarity corresponding to the work you are
performing.
<<<<
Note
>>>>
•
Use the polarity indicated for the welding rods being used if so indicated.
•
When welding with 2 persons using different polarities for the same base material,
a single worker must not hold 2 holders because the voltage between the 2 holders
could become high and there may be a danger.
Polarity
Rod
Indication
Application
Connecting Method
Straight
Polarity
DC-
Shielded metal arc welding of
structures and similar items
Scratch start TIG welding
+
(positive) terminal
:
Earth (Base material)
-
(negative) terminal
:
Holder (welding rod)
Reverse
Polarity
DC+
Shielded metal arc welding of
laminates, weld overlays, stainless
steel and similar materials
Gouging
+
(positive) terminal
:
Holder (welding rod)
-
(negative) terminal
:
Earth (Base material)
8.
Using as a Welder