- 19 -
■
Engine Oil Selection
Use a diesel-type engine oil with a viscosity that is appropriate for the outdoor air
temperature (refer to the table).
<<<<
Note
>>>>
•
Use oil with a quality of CD class or better (API classification).
Temperature/Engine Oil Relationship
Temperature
+
20
°
C or more
+
10
°
C
~+
20
°
C
-
10
°
C
~+
40
°
C
Oil Viscosity
SAE30
SAE20
SAE 10W/30
6-2
.
.
.
.
Cooling Water Inspection
Caution: Burn
•
Never open the radiator cap during operation or immediately after
stopping the equipment. Hot cooling water and steam will spurt out.
Check that the sub tank cooling water level is within the range of "FULL" and
"LOW" .
If the cooling water level lower than "LOW", add water to both the sub tank and
radiator.
(1) Adding Water to the Sub Tank
1) Remove the sub tank cap.
2) Pour cooling water into the sub tank
until it reaches the "FULL" level.
3) Install the sub tank cap.
(2) Adding Water to the Radiator
1) Open the top plate.
2) Remove the radiator cap.
3) Pour cooling water into the radiator
through the inlet port until it reaches
the mouth of the port.
4) Tighten the radiator cap.
5) Close the top plate.
<<<<
Note
>>>>
•
Use a long-life coolant (LLC) in order to
prevent freezing and rust. (An LLC with a
30% mixing ratio is used when shipped
from the factory.)
•
Use an LLC mixing ratio in the range 30%
to 45% in accordance with the outdoor air
temperature.
•
Change the LLC every 2,000 hours or
every 2 years.
Mixing Ratio Guide
Min. Temp.
-
15
°
C
-
20
°
C
-
30
°
C
Mixing Ratio
30
%
35
%
45
%
Sub Tank
Sub Tank
Cap
Sub Tank
FULL
LOW
Radiator Cap
Water
Inlet
Top Plate