AR-BC260 TROUBLESHOOTING 11 - 28
U6
20
Case 1
Cause
Improper connection or
disconnection of the
connector and the harness.
Check &
Remedy
Check the connector and
the harness in the
communication line.
Case 2
Cause
LCC control PWB trouble
Check &
Remedy
Replace the LCC control
PWB.
Case 3
Cause
Control PWB (PCU) trouble
Check &
Remedy
Replace the control PWB
(PCU).
Case 4
Cause
Malfunction caused by
noises
Check &
Remedy
Turn OFF/ON the power to
cancel the error.
Main
code
Sub
code
Title
LCC transport motor trouble
U6
21
Display
Lamp/Message
Phenomenon Detail
• The encoder input value
does not change in
0.06sec after turning on
the motor.
• The encoder input
changes after the speci-
fied time from turning off
the motor. (100 or more
counts are made in
0.1sec after 5sec.)
Section
—
Case 1
Cause
Motor lock, motor RPM
abnormality. Over current to
the motor, saddle finisher
control PWB trouble
Check &
Remedy
Use SIM 4-3 to check the
transport motor operation.
Main
code
Sub
code
Title
LCC 24V power abnormality
U6
22
Display
Lamp/Message
Phenomenon Detail
DC 24V is not supplied to
the LCC.
Section
—
Case 1
Cause
Improper connection or
disconnection of the
connector and the harness.
Check &
Remedy
Check the connector and
the harness in the power
line.
Turn OFF/ON the power to
cancel the error.
Case 2
Cause
LCC control PWB trouble
Check &
Remedy
Turn OFF/ON the power to
cancel the error.
Case 3
Cause
Power supply unit trouble
Check &
Remedy
Turn OFF/ON the power to
cancel the error.
Main
code
Sub
code
Title
LCC communication trouble
Main
code
Sub
code
Title
Desk incompatibility trouble
U6
50
Display
Lamp/Message
Phenomenon Detail
Connection of a desk which
is not compatible with the
AR-BC260 is detected.
Section
Desk
Case 1
Cause
Connection of a desk (AR-
D17/AR-D18/AR-D19)
which is not compatible with
the AR-BC260 is detected.
Check &
Remedy
Connect the AR-D18N/AR-
D19N.
Main
code
Sub
code
Title
LCC incompatibility trouble
U6
51
Display
Lamp/Message
Phenomenon Detail
Connection of LCC which is
not compatible with the AR-
BC260 is detected.
Section
LCC
Case 1
Cause
Connection of the AR-LC5
which is not compatible with
the AR-BC260 is detected.
Check &
Remedy
Connect the AR-LC8.
Main
code
Sub
code
Title
RIC communication trouble
U7
00
Display
Lamp/Message
Phenomenon Detail
RIC communication error,
communication test error
when turning on the power
or after canceling the
exclusive simulation.
Section
RIC
Case 1
Cause
Improper connection or
disconnection of the
connector and the harness.
RIC control PWB trouble,
control PWB (PCU) trouble,
malfunction caused by
noises.
Check &
Remedy
Turn OFF/ON the power to
cancel the error.
Check the connector and
the harness in the
communication line.
Main
code
Sub
code
Title
CPT-ASIC trouble (MFP PWB
trouble)
UC
02
Display
Lamp/Message
Phenomenon Detail
Access abnormality to CPT-
ASIC (ASIC does not
operate normally.)
Section
MFP PWB
Case 1
Cause
CPT-ASIC abnormality
MFP PWB abnormality
Check &
Remedy
Turn OFF/ON repeatedly. If
the trouble is not canceled,
replace the MFP PWB.