AR-BC260 SIMULATION 9 - 62
3. Press the [EXECUTE] key.
∗
If there is no paper on the duplex tray, one sheet of the
selected paper is fed and transported to the duplex tray.
Then the entered value in procedure 3 is set and the
alignment plate moves according to the home position
corresponding to the entered value.
∗
The paper sizes which can be used for transport and
alignment plate adjustment with SIM52-01 are LT, LTR, A4,
A4R, B5, B5R, 16K, and 16KR only. (For the other sizes,
"FEED ENABLE" occurs.)
(Set items)
• When the set value is changed by 1, it is changed by about
0.2mm. When the set value is increased, the alignment plate
paper width is narrowed. The adjustment value can be adjusted
in the increment of ±50 with 50 as the center value.
(Set value (for manual adjustment))
(Manual adjustment display)
(Items to be set)
Item
Set range
Default
A
Intermediate tray alignment plate
adjustment value (Manual feed)
0 – 99
50
B
Intermediate tray alignment plate
adjustment value (Cassette 1)
0 – 99
50
C
Intermediate tray alignment plate
adjustment value (Cassette 3)
0 – 99
50
D
Intermediate tray alignment plate
adjustment value (Cassette 4)
0 – 99
50
E
Intermediate tray alignment plate
adjustment value (LCC)
0 – 99
50
53
53
-08
Purpose
Adjustment
Function
(Purpose)
Used to adjust the document feeder unit document
scanning position.
Section
Automatic document feeder
Item
Operation
Operation/
Procedure
The automatic or manual adjustment of the
document mirror scanning position of the document
feeder unit is performed.
Press [AUTO] key for the automatic adjustment, and
press [MANUAL] for the manual adjustment.
[Automatic adjustment]
1. The adjustment value stored in the EEPROM is
displayed in "AUTO ADJUST VALUE."
2. When [EXECUTE] key is pressed, the
adjustment value is automatically obtained and
displayed and saved in the EEPROM at the
same time.
[Manual adjustment]
1. Enter the set value with the 10-key and press the
[OK] key to store the set value.
Item
Description
Set range Default
A MANUAL
ADJUST VALUE
Document feeder unit
scanning position
adjustment (for
manual adjustment)
1 – 99
50
60
60
-01
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of ICU PWB image
DRAM read/write.
Section
ICU (Memory)
Item
Operation
Operation/
Procedure
Press the [EXECUTE] key, and memory read/write
operation check is started.
After completion of check, the result is displayed
with NG or OK.
61
61
-04
Purpose
Adjustment
Function
(Purpose)
Used to adjust the scanner (writing) unit (LED array
unit) skew.
Section
Scanner (writing)
Item
Operation
Operation/
Procedure
1. Set the print conditions of the scanner (writing)
unit (LED array unit) skew adjustment pattern.
2. Press the [EXECUTE] key.
The scanner (writing) unit (LED array unit) skew
adjustment pattern is printed.
Display
Content
Min.
Value
Max.
Value
Default
A PATTERN
Print pattern specification
1: SKEW--- Used to
check scan tilt.
2: FOCUS --- Used to
check/adjust focus.
1
2
1
B LINE PITCH Dot print width (N-1)
specification
1
10
7
C POSITION
Pattern output area
selection
1
12
6