![Sharp AR-BC260 Скачать руководство пользователя страница 198](http://html.mh-extra.com/html/sharp/ar-bc260/ar-bc260_service-manual_365275198.webp)
AR-BC260 SIMULATION 9 - 60
14: Main scanning direction rough adjustment 1 Yellow patch print
error
15: Sub scanning direction rough adjustment 1 Cyan patch print
error
16: Sub scanning direction rough adjustment 1 Magenta patch
print error
17: Sub scanning direction rough adjustment 1 Yellow patch print
error
18: Main scanning direction rough adjustment 2 Cyan patch print
error
19: Main scanning direction rough adjustment 2 Magenta patch
print error
20: Main scanning direction rough adjustment 2 Yellow patch print
error
21: Sub scanning direction rough adjustment 2 Cyan patch print
error
22: Sub scanning direction rough adjustment 2 Magenta patch
print error
23: Sub scanning direction rough adjustment 2 Yellow patch print
error
98: Regist sensor error
99: Other error
When the adjustment value is changed, the image losses at the
four corners are changed uniformly.
2. The self print chart is printed, and the machine is brought into
the self print chart scan standby mode.
3. Select [SCAN], and the outputted self print chart is scanned.
4. Select [FINISH] to display the result display menu.
[DATA]: The scanned data are displayed.
• When the set value is 50 at transfer ON timing, the transfer
operation is turned on immediately when the paper lead edge
passes beneath the drum.
• When the set value is 50 at transfer OFF timing, the transfer
operation is turned off immediately when the paper rear edge
passes beneath the drum.
• When the transfer ON/OFF timing value is decreased, the
transfer ON/OFF timing is advanced for the paper.
• When the transfer ON/OFF timing value is increased, the
transfer ON/OFF timing is delayed for the paper.
• Change of ±1 corresponds to about 10ms. The set range is –
490 to +490ms
50
-27
Purpose
Adjustment
Function
(Purpose)
Used to adjust image loss in the FAX/scanner mode.
Section
FAX/Scanner
Item
Picture quality
Image position
Operation/
Procedure
1. Select the adjustment mode with the scroll key.
2. Enter the adjustment value at the selected point,
and press the [OK] key. The entered value is set.
Display
Content
Min.
Value
Max.
Value
Default
A
FAX MODE image loss
0
99
20
B
PUSH SCAN MODE image loss
0
99
30
C
PULL SCAN MODE image loss
0
99
0
50
-28
Purpose
Adjustment
Function
(Purpose)
Used to adjust automatic void (service installation
adjustment).
Item
Picture quality
Image position
Operation/
Procedure
1. [ALL OPTION CS]: Select "For service
installation adjustment."
[CS ADJ]: Individual adjustment of cassette
[OC ADJ]: OC adjustment
[SPF ADJ]: SPF adjustment
[PRINT]: When [AUTO] is selected, the self print for
adjustment of CS1 and that for adjustment of MFT
are printed. (When [SPF] is selected, the output is
made from the currently set cassette.)
51
51
-01
Purpose
Adjustment
Function
(Purpose)
Used to adjust the transfer voltage ON timing.
Section
Process (Photoconductor, developing,
transfer, cleaning)
Transfer
Item
Operation
Operation/
Procedure
1. Select the adjustment mode with the scroll key.
2. Enter the set value with the 10-key and press the
[OK] key to set the entered value.
Item
Description on item
Set
range
Default
A NORMAL ON
TIMING
Used to set the transfer
ON timing for the paper
lead edge except for OHP.
1 – 99
40
B NORMAL OFF
TIMING
Used to set the transfer
OFF timing for the paper
rear edge except for OHP.
1 – 99
60
C OHP ON
TIMING
Used to set the transfer
ON timing for the lead
edge of OHP.
1 – 99
40
D OHP OFF
TIMING
Used to set the transfer
OFF timing for the rear
edge of OHP.
1 – 99
60