AR-BC260 SIMULATION 9 - 3
B. Simulation list
(1) Main/ Sub
Code
Function (Purpose)
Purpose
Section
Item
Main
Sub
1
1
Used to check the operations of the
scanner unit and its control circuit.
Operation test/check
Scanner (reading)
Operation
2
Used to check the sensors and
detectors in the scanner section and
the related circuits.
Operation test/check
Scanner (reading)
Operation
5
Used to check the scanner
(scanning) unit and its control circuit.
Operation test/check
Scanner (reading)
Operation
2
2
Used to check the operations of the
sensors and detectors in the
document feeder unit and their
related circuits.
Operation test/check
Automatic document
feeder
Operation
3
Used to check the operations of the
motors, solenoids, and the PS clutch
in the document feeder unit.
Operation test/check
Automatic document
feeder
Operation
3
2
Used to check the operations of the
sensors and detectors in the finisher
and the related circuits.
Operation test/check
Finisher
Operation
3
Used to check the loads in the
finisher and the control circuit.
Operation test/check
Finisher
Operation
10
Used to adjust the sections in the
finisher.
Operation test/check
Finisher
Operation
4
2
Used to check the operations of the
desk/large capacity tray sensors and
detectors and the related circuits.
Operation test/check
Paper feed
Operation
3
Used to check the operations of the
desk/large capacity tray loads and
the control circuit.
Operation test/check
Paper feed
Operation
5
Used to check the operations of the
clutch TRC and the monitor.
Operation test/check
Paper feed
Operation
5
1
Used to check the operations of the
display lamp (LED)/LCD on the
operation panel and the control
circuits.
Operation test/check
Operation (Display,
procedure)
Operation
2
Used to check the operations of the
heater lamp and its control circuit.
Operation test/check
Fusing
Operation
3
Used to check the operations of the
scanner lamp and its control circuit.
Operation test/check
Scanner (reading)
Operation
4
Used to check the operations of the
discharge lamp and its control circuit.
Operation test/check
Process
(Photoconductor,
developing, transfer,
cleaning)
Others
Operation
6
1
Used to check the operations of the
loads (clutches and solenoids) in the
paper transport system, transfer, and
fusing, and the control circuit.
Operation test/check
Paper transport (paper
exit, switchback,
transport), transfer,
fusing
Operation
2
Used to check the operations of the
fan motors and the control circuits.
Operation test/check
Others
Operation
7
1
Used to set the aging conditions.
Setting/Operation test/
check
Operation
6
Used to set the cycle of intermittent
aging.
Setting/Operation test/
check
Operation
8
Used to set Yes/No of warm-up time
display.
Setting/Operation test/
check
Operation
9
Used to check the image quality and
operations of each color.
Operation test/check
Others
Picture quality
8
1
Used to check and adjust the
operations of the developing bias
voltage of each color and the control
circuit.
Adjustment/Operation
test/check
Process
(Photoconductor,
developing, transfer,
cleaning)
2
Used to check and adjust the
operation of each print mode main
charger grid voltage and the control
circuit.
Adjustment/Operation
test/check
Process
(Photoconductor,
developing, transfer,
cleaning)
6
Used to check and adjust the
operation of the transfer charger
current and the control circuit.
Adjustment/Operation
test/check
Process
(Photoconductor,
developing, transfer,
cleaning)
Transfer
9
2
Used to check the operation of the
sensors and detectors in the inverter/
duplex section and the control circuit.
Operation test/check
Inverter/Duplex
Operation
3
Used to check the operations of the
loads (motor, clutch, solenoid) in the
inverter/duplex section and the
control circuits.
Operation test/check
Inverter/Duplex
Operation