AR-BC260 TROUBLESHOOTING 11 - 26
Main
code
Sub
code
Title
EEPROM read/write error (PCU)
U2
90
Display
Lamp/Message
Phenomenon Detail
EEPROM version error
EEPROM write error
Section
—
Case 1
Cause
EEPROM trouble,
Insertion of EEPROM which
is not initialized or defective.
Check &
Remedy
1. Check that the EEPROM
is properly inserted.
2. Use SIM 16 to cancel the
error.
Case 2
Cause
PCU PWB EEPROM
access circuit trouble
Check &
Remedy
1. To prevent against
deletion of the counter
data and the adjustment
data, record them with
the simulation. (When a
printer option is installed,
use SIM 22-1 to record
the counter data and the
adjustment data.)
2. Replace the PCU PWB.
3. Use SIM 16 to cancel the
error.
Main
code
Sub
code
Title
Adjustment value check sum error
(PCU)
U2
91
Display
Lamp/Message
Phenomenon Detail
EEPROM (PCU) check sum
error
Section
—
Case 1
Cause
EEPROM trouble
Check &
Remedy
1. Check that the EEPROM
is properly inserted.
2. Use SIM 16 to cancel the
error.
Case 2
Cause
Control circuit freeze
caused by noises, PCU
PWB EEPROM access
circuit trouble
Check &
Remedy
1. To prevent against
deletion of the counter
data and the adjustment
data, record them with
the simulation. (When a
printer option is installed,
use SIM 22-1 to record
the counter data and the
adjustment data.)
2. Replace the PCU PWB.
3. Use SIM 16 to cancel the
error.
Main
code
Sub
code
Title
ADU alignment plate operation
abnormality
U4
02
Display
Lamp/Message
Phenomenon Detail
The alignment plate does
not move from the home
position within 1sec when it
must move. Return to the
home position is not
detected for 5sec or more.
Section
ADU
Case 1
Cause
Home position sensor
trouble
Check &
Remedy
Use SIM 9-2 to detect the
home position sensor.
Case 2
Cause
Alignment plate shift motor
trouble
Check &
Remedy
Use SIM 9-4 to check the
alignment plate operation.
Case 3
Cause
Disconnection of the
harness between the ADU
control PWB and the motor
sensor.
Check &
Remedy
Check connection of the
harness between the ADU
control PWB and the motor
sensor.
Case 4
Cause
Alignment plate operation
belt, gear breakage or
improper adjustment
Check &
Remedy
Remove the ADU, and
check for breakage of the
gear and the belt.
Main
code
Sub
code
Title
Desk communication trouble
U6
00
Display
Lamp/Message
Phenomenon Detail
Desk communication error,
communication test error
when turning on the power
or after canceling the
exclusive simulation.
Section
Desk
Case 1
Cause
Improper connection or
disconnection of the
connector and the harness.
Check &
Remedy
Check the connector and
the harness in the
communication line.
Turn OFF/ON the power to
cancel the error.
Case 2
Cause
Desk control PWB trouble,
control PWB (PCU) trouble,
malfunction caused by
noises
Check &
Remedy
Turn OFF/ON the power to
cancel the error.