AR-BC260 SIMULATION 9 - 20
(Items to be selected/replaced)
(Check item)
While the load operates, the [EXECUTE] key is highlighted.
When the [EXECUTE] key is pressed under this state, the
operation of the load can be interrupted.
Item
Print mode
Standard setting value
(Default)
Adjustment
range
Output voltage (Kv)
K
C
M
Y
K
C
M
Y
A
PLAIN SPX CL
Color
Normal paper
78mm/s
153
141
119
119
51 - 255
2
2
2
2
B
PLAIN DPX CL
Color
Normal paper(Duplex mode)
78mm/s
168
155
129
129
2.3
2.3
2.3
2.3
C
OHP1 CL
Color
Transparency film 1
78mm/s
204
187
153
153
3
3
3
3
D
OHP2 CL
Color
Transparency film 2
58.5mm/s
137
150
153
163
1.7
2.2
3
3.3
E
HEAVY P1 SPX CL
Color
Thick paper 1
58.5mm/s
158
146
122
122
2.1
2.1
2.1
2.1
F
HEAVY P1 DPX CL
Color
Thick paper 1(Duplex mode)
58.5mm/s
188
173
142
142
2.7
2.7
2.7
2.7
G
HEAVY P2 CL
Color
Thick paper 2
58.5mm/s
173
159
132
132
2.4
2.4
2.4
2.4
H
ENVELOPE CL
Color
Envelope
78mm/s
153
141
119
119
2
2
2
2
I
PLAIN SPX BW
B & W
Normal paper
117mm/s
168
2.3
J
PLAIN DPX BW
B & W
Normal paper(Duplex mode)
117mm/s
178
2.5
K
OHP1 BW
B & W
Transparency film 1
78mm/s
204
3
L
OHP2 BW
B & W
Transparency film 2
58.5mm/s
137
1.7
M
HEAVY P1 SPX BW
B & W
Thick paper 1
58.5mm/s
147
1.9
N
HEAVY P1 DPX BW
B & W
Thick paper 1(Duplex mode)
58.5mm/s
178
2.5
O
HEAVY P2 BW
B & W
Thick paper 2
58.5mm/s
163
2.2
P
ENVELOPE BW
B & W
Envelope
117mm/s
168
2.3
9
9
-2
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of the sensors and
detectors in the inverter/duplex section and the
control circuit.
Section
Inverter/Duplex
Item
Operation
Operation/
Procedure
The operations of sensors and detectors in the
inverter/duplex section are displayed.
The active sensors and detectors are highlighted.
BPPD1
Inverter transport detection 1
BPPD2
Inverter transport detection 2
BPRD
Inverter reverse detection
BPOD
Inverter paper exit detection
BPFD
Inverter full detection
BDD1
Inverter door detection 1
BDD2
Inverter door detection 2
APPD1
ADU transport detection 1
APPD2
ADU transport detection 2
APHPS
ADU alignment plate home position
POD1
Machine paper exit detection
BYSET
Inverter installation detection
ADUDSET
ADU installation detection
ADUSET
ADU door open/close detection
9
-3
Purpose
Operation test/check
Function
(Purpose)
Used to check the operations of the loads (motor,
clutch, solenoid) in the inverter/duplex section and
the control circuits.
Section
Inverter/Duplex
Item
Operation
Operation/
Procedure
1. Select the load to be checked with the 10-key
pad.
2. Press the [EXECUTE] key.
The load selected in procedure 1 operates.
BIM
Inverter paper entry motor
BRMFW
Inverter reverse motor (Normal rotation)
BRMRV
Inverter reverse motor (Reverse rotation)
BGSOL
Inverter gate solenoid
BTMFW
Inverter transport motor (Normal rotation)
BTMRV
Inverter transport motor (Reverse rotation)
ATM
ADU transport motor
APAM
ADU alignment motor
ATRC
ADU transport clutch