9
Parameterization via PROFIdrive dataset 47
Structure of the PROFINET parameter channel
Manual – PROFINET IO Interfaces, Field Distributors
118
Negative parameter response
The following table shows the coding of a negative response of a MOVILINK
®
service.
Bit 7 is entered in the response ID if the response is negative.
Service
WRITE.re-
sponse
Description
API
0
Fixed setting = 0
Slot_Number
0
Random (is not evaluated)
Subslot_Num-
ber
1
Fixed setting = 1
Index
47
Index of the dataset for the parameter request; con-
stant index 47
Length
8
8 byte user data in response buffer
Byte Field
Value
Description
0
Response reference
0x01
Mirrored reference number of the paramet-
erization order
1
Response ID
0xC0
Negative MOVILINK
®
response
2
Axis
0x02
Mirrored axis number of the MOVIMOT
®
drive
3
No. of parameters
0x01
1 parameter
4
Format
0x44
Error
5
No. of values
0x01
1 error code
6, 7
Error value
0x0811
MOVILINK
®
return code
e.g. Error class 0x08, Add. code 0x11
22870857/EN – 12/2016