8
PROFINET IO configuration
PROFINET IO controller – configuration
Manual – PROFINET IO Interfaces, Field Distributors
89
8.2.4
PROFINET IO controller – configuration
Configure the PROFINET IO controller as follows:
ü
Make sure that the "Device view" tab is open.
1. Use the mouse to drag the "MFE V1.2 3MM" entry on the PROFINET IO system.
2. Right-click on the system and select the menu item "Assign device names" from
the context menu. Enter the PROFINET IO station name.
ð
This name must later correspond to the PROFINET IO device name set in the
MFE PROFINET IO interface.
19209922955
3. Mark the symbol of the MFE PROFINET IO interface.
4. Switch to the "Device view" tab.
5. Delete the slot entries that are no longer required.
19209925899
6. Click on a slot.
ð
The hardware catalog opens.
22870857/EN – 12/2016