11
Supplementary field distributor startup information
MF../MM../Z.8. field distributor
Manual – PROFINET IO Interfaces, Field Distributors
138
11.3.2
Checking the connection type of the motor
Use the following figure to check that the selected connection type is identical for the
field distributor and the connected motor.
U1
V1
W1
W2 U2 V2
U1
V1
W1
W2 U2 V2
W
m
1162529803
INFORMATION
For brake motors: Do not install brake rectifiers inside the terminal box of the motor!
11.3.3
Internal wiring of the MOVIMOT
®
inverter in the field distributor
2
4
V
T
H
L
R
1
3
1
4
1
5
L
1
L
2
L
3
L
1
L
2
L
3
2
4
V
TH
[4]
[1]
[2]
[3]
X4
ϑ
9007200441675147
[1] DIP switches for setting the connection type (
W
or
m
)
Make sure that the connection type of the connected motor corresponds
with the setting of the DIP switch.
[2]
Note the enabled direction of rotation
(Both directions of rotation are enabled as standard)
Both directions of rota-
tion are enabled
Only
CCW
direction of
rotation is enabled
Only
CW
direction of rotation is
enabled
24V
TH
L
R
24V
TH
L
R
24V
TH
L
R
TH
TH
TH
ϑ
ϑ
ϑ
[3] Connection for internal braking resistor (in motors without brake only)
[4] Maintenance switch
22870857/EN – 12/2016