6
Electrical installation
Installation instructions for fieldbus interfaces, field distributors
Manual – PROFINET IO Interfaces, Field Distributors
44
6.2.7
Notes on PE connection
WARNING
Electric shock due to faulty ground connection or faulty equipotential bonding.
Severe, fatal injuries
•
The permitted tightening torque for the retaining screws is 2.0 – 2.4 Nm.
•
Make sure to install the ground connection and equipotential bonding correctly.
Prohibited assembly
Recommendation:
Assembly with forked cable lug
Permitted for all cross sections
Assembly with solid connecting
wire
Permitted for cross section
up to max. 2.5 mm
2
[1]
M5
2.5 mm²
M5
[1]
Forked cable lug suitable for M5 PE screws
Earth-leakage currents of ≥ 3.5 mA can occur during normal operation. To meet the
requirements of EN 61800-5-1, observe the following notes:
•
The protective earth (PE) connection must meet the requirements for plants with
high earth-leakage currents.
•
This usually means
– installing a PE connection cable with a minimum cross section of 10 mm
2
– or installing a second PE connection cable via separate terminals that must not
be smaller than the cable cross section of the supply system cable.
22870857/EN – 12/2016