6
Electrical installation
Connection of MFZ29 field distributor with MFE52
Manual – PROFINET IO Interfaces, Field Distributors
53
6.6
Connection of MFZ29 field distributor with MFE52
6.6.1
Terminal positions
The following figure shows the position of the terminals and PE connections of the
field distributor as an example:
1415
13
12
11
1
2
3
4
5
1
2
3
4
5 6
7
8 9
12
11
10
1
2
3
4
5 6
7
8 9
12
11
10
1
2
3
4
5 6
7
8 9
12
11
10
X6_1
X4_1
X20
X21
MM1
MM2
MM3
X1
X6_2
X4_2
X6_3
X4_3
[15]
[4]
[5]
[6]
MM1
[14]
[2]
[3]
[1]
[12]
[11]
[9]
[8]
PE
[17]
PE
[16]
MM2
PE
[13]
PE
[10]
PE
[7]
MM3
18210880779
[1]
X1
Supply system terminals
[2]
X20
24 V distributor terminals
[3]
X21
24 V supply terminals (24 V power bus)
[4]
MM1
Slot for MOVIMOT
®
inverter 1 with RS485 address = 1
[5]
MM2
Slot for MOVIMOT
®
inverter 2 with RS485 address = 2
[6]
MM3
Slot for MOVIMOT
®
inverter 3 with RS485 address = 3
[7]
PE MM3
Motor 3 PE connection
[8]
X4_3
Motor 3 power terminals (U, V, W, brake)
[9]
X6_3
Motor 3 control terminals
[10]
PE MM2
Motor 2 PE connection
[11]
X4_2
Motor 2 power terminals (U, V, W, brake)
[12]
X6_2
Motor 2 control terminals
[13]
PE MM1
Motor 1 PE connection
[14]
X4_1
Motor 1 power terminals (U, V, W, brake)
[15]
X6_1
Motor 1 control terminals
[16]
PE
PE connection
[17]
PE
External PE connection/equipotential bonding
22870857/EN – 12/2016