Parameterization via PROFIdrive dataset 47
Structure of the PROFINET parameter channel
Manual – PROFINET IO Interfaces, Field Distributors
110
Field
Data type
Values
Attributes
Unsigned8
For SEW MOVILINK® (Request ID = 0x40):
0x00 No service
0x01 READ parameter
0x20 WRITE parameter
0x40 Read minimum
0x50 Read maximum
0x60 Read default
0x80 Read attribute
0x90 Read EEPROM
0xA0 – 0xF0 reserved
SEW data transport:
0x10 value
No. of ele-
ments
Unsigned8
0x00 for parameters that are not indexed
0x01 – 0x75 Quantity 1 – 117
Parameter
Number
Unsigned16 0x0000 – 0xFFFF MOVILINK
®
parameter index
Subindex
Unsigned16 0x0000 SEW: always 0
Format
Unsigned8
0x43 double word
0x44 error
No. of Values
Unsigned8
0x00 – 0xEA Quantity 0 – 234
Error Value
Unsigned16 MOVILINK
®
additional code low
For SEW MOVILINK
®
16 bit error value