9
Parameterization via PROFIdrive dataset 47
Structure of the PROFINET parameter channel
Manual – PROFINET IO Interfaces, Field Distributors
123
After sending this WRITE.request, the WRITE.response is received. If there was no
status conflict in processing of the parameter channel, a positive WRITE.response
results. Otherwise, the status fault is located in Error_code_1.
Query parameter response
The following table shows the coding of the WRITE.request user data including the
PROFINET header.
Service
Write.request Description
Slot_Number
X
Random (is not evaluated)
Index
47
Index of the data set
Length
240
Maximum length of response buffer in the
PROFINET controller
Positive response to "WRITE parameter"
Service:
READ.re-
sponse
Description
Slot_Number
0
Random (is not evaluated)
Index
47
Index of the data set; constant index 47
Length
4
4 byte user data in response buffer
Byte Field
Value
Description
0
Response reference
0x01
Mirrored reference number from the
parameter setting request
1
Response ID
0x02
Positive PROFIdrive response
2
Axis
0x02
Mirrored axis number of the
MOVIMOT
®
drive (1, 2, 3)
3
No. of parameters
0x01
1 parameter
22870857/EN – 12/2016