![SEW-Eurodrive MOVIGEAR DAC B Скачать руководство пользователя страница 90](http://html1.mh-extra.com/html/sew-eurodrive/movigear-dac-b/movigear-dac-b_operating-instructions-manual_1250343090.webp)
90
Operating Instructions – MOVIGEAR® DAC-B
6
Startup with binary slave GLK30A in "Expert" mode
Startup
6.5.3
Example "Fine adjustment of setpoint f2 using MOVITOOLS
®
MotionStudio"
1. It is essential that you observe the startup instructions.
2. Activate Expert mode as described in chapter "Startup with binary slave GLK30A in
"Expert" mode".
3. Connect the PC to the MOVIGEAR
®
inverter.
4. Connect the MOVIGEAR
®
inverter to the voltage supply.
5. Start MOVITOOLS
®
MotionStudio.
6. Create a project and network.
7. Configure the communication channel at the PC.
8. Perform an online scan.
You will get the following or a similar result:
9. Open the context menu of the MOVIGEAR
®
command pcb [1] by clicking the right
mouse button and select the menu item "Startup" / "Parameter tree".
10.Open the folder "Setpoint selection" [3].
Deactivate switch f2 by ticking the check box "Switch f2" [4].
11.Open the folder "Setpoints" [2].
2757318923
[1] MOVIGEAR
®
command pcb
[2] MOVIGEAR
®
power section
[3] Setpoint selection folder
[4] Check box for switch f2
[4]
[3]
[1]
[2]
0
0