Operating Instructions – MOVIGEAR® DAC-B
129
8
Description of power section parameters
Parameters
8.3.4
Unit functions
Command pcb parameters \ unit functions \ setup
Factory setting
index 8594.0
If you set this parameter to "Delivery state", all parameters that have a factory setting
and can not be set using DIP switches t1/f2 or setpoint potentiometer f1 are reset to their
factory setting values.
For those parameters that can be set using switches t1 / f2 or setpoint potentiometer f1
during startup in "Easy mode", the setting of the mechanical setting element becomes
active when the factory setting "Delivery state" is selected.
8.4
Description of power section parameters
8.4.1
Display values
Power section parameters \ display values \ process values
Speed
index 8318.0
The parameter indicates the motor speed:
• Unit: [rpm]
• Reso/– 0.2 rpm
User display
index 8501.0
The user display is defined by the following parameters:
• 8747.0 Scaling factor for user display numerator
• 8748.0 Scaling factor for user display denominator
• 8772.0/8773.0 User-defined unit
• Unit: [Text]
Apparent output
current
index 8321.0
The parameter indicates the apparent current:
• Unit: [% I
N
]
Active output
current
index 8322.0
The parameter indicates the active current. The display value is positive when torque is
in positive sense of rotation; negative when torque is in negative sense of rotation.
• Unit: [% I
N
]
Apparent output
current
index 8326.0
The parameter indicates the apparent output current:
• Unit: [A]
DC link voltage
index 8325.0
The parameter indicates the voltage measured in the DC link circuit:
• Unit: [V]
Unit utilization
index 8730.0
The parameter indicates the unit utilization Ixt:
• Unit: [%]
Heat sink
temperature
index 8327.0
The parameter indicates the heat sink temperature of the power section:
• Unit: [°C]
0