62
Operating Instructions – MOVIGEAR® DAC-B
5
Connection of MOVIGEAR
®
Electrical Installation
5.4
Connection of MOVIGEAR
®
DANGER
No safe disconnection of MOVIGEAR
®
.
Severe or fatal injuries.
• Do not use the 24 V output (terminals 6, 7, 16, 17) for safety-related applications
with MOVIGEAR
®
.
• The STO input may only be jumpered with 24 V if MOVIGEAR
®
does not perform
any safety function.
2381830923
Local operation
Automatic mode active
Local mode active
Functions of the CW/Stop and CCW/Stop
terminals when local mode is active:
Direction of rotation
CW
active
Direction of rotation
CCW
active
Functions of terminals f1/f2 when local mode
is active:
Setpoint
f1
active
Setpoint
f2
active
[1] Integrated 24 V supply
[2] CW / stop
[3] CCW / stop
[4] Setpoint changeover f1/f2
[5] Automatic mode/local mode
[6] Signal relay (contact closed = ready for operation)
[7] Assignment see chapter "Plug connector assignment"
[8] Assignment see chapter "Plug connector assignment"
L1
L2
L3
PE
K11
F11/F12/F13
L1
L2
L3
MOVIGEAR DAC B
®
[2]
[3]
[4]
[6]
[7]
13 K1b
3 K1a
2 STO
̶ IN
1 STO + IN
12 STO
̶ OUT
11 STO + OUT
14 DI02 L
4 DI01 R
7 0V24_O
6 24V_O
17 0V24_O
16 24V_O
[5]
[1]
[1]
5 DI03 f1/f2
15 DI04 Auto/local
Local operation
Connection
Sensor input
[8]
2
1
4
3
Connection
AS-Interface
1
4
3
2
5
16 24V_O
14 DI02 L
4 DI01 R
5 DI03 f1/f2
15 DI04 auto/local
16 24V_O
14 DI02 L
4 DI01 R
5 DI03 f1/f2
15 DI04 auto/local
4 DI01 R
14 DI02 L
16 24V_O
4 DI01 R
14 DI02 L
16 24V_O
4 DI01 R
14 DI02 L
16 24V_O
5 DI03
f1/f2
4 DI01 R
14 DI02 L
16 24V_O
5 DI03
f1/f2