![SEW-Eurodrive MOVIGEAR DAC B Скачать руководство пользователя страница 122](http://html1.mh-extra.com/html/sew-eurodrive/movigear-dac-b/movigear-dac-b_operating-instructions-manual_1250343122.webp)
122
Operating Instructions – MOVIGEAR® DAC-B
8
Overview of power section parameters
Parameters
Unit functions
Index
Parameter name
MOVITOOLS
®
MotionStudio
Display
(Range / factory setting)
MOVILINK
®
scaling
Power section parameters \ unit functions \ setup
8594.0
Factory setting
•
0 = No
•
1 = Standard
•
2 = Delivery state
•
3 = Basic initialization
8595.0
Parameter lock
•
0 = No
•
1 = Yes
Power section parameters \ unit functions \ error monitoring
Programmable responses
9729.16
Response ext. fault
•
0 = No response
•
1 = Display only
•
2 = Output stage inhibit / locked
•
3 = Emergency stop / locked
•
4 = Stop / locked
•
5 = Output stage inhibit / waiting
•
6 = Emergency stop / waiting
•
7 = Stop / waiting
9729.4
Mains phase failure response
•
0 = No response
•
1 = Display only
•
2 = Output stage inhibit / locked
•
3 = Emergency stop / locked
•
4 = Stop / locked
•
5 = Output stage inhibit / waiting
•
6 = Emergency stop / waiting
•
7 = Stop / waiting
9729.9
TF signal response
•
0 = No response
•
1 = Display only
•
2 = Output stage inhibit / locked
•
3 = Emergency stop / locked
•
4 = Stop / locked
•
5 = Output stage inhibit / waiting
•
6 = Emergency stop / waiting
•
7 = Stop / waiting
Error acknowledgement
8617.0
Manual reset
•
0 = No
•
1 = Yes
Power section parameters \ unit functions \ scaling of actual speed value
8747.0
Scaling factor for user display numerator
1 – 65535
8748.0
Scaling factor for user display denominator
1 – 65535
8772.0
User-defined unit
[Text]
0
0
I
Содержание MOVIGEAR DAC B
Страница 2: ...SEW EURODRIVE Driving the world...