13
Technical data of MOVIGEAR
®
Technical Data and Dimension Sheets
13
Technical Data and Dimension Sheets
13.1 Technical data of MOVIGEAR
®
13.1.1 General technical data
13.1.2 Ambient temperature
MOVIGEAR
®
type
MGF..2
MGF..4
MGF..4/ET
Torque class
M
200 Nm
400 Nm
Supply voltages
Permitted range
V
line
3 x AC 380 V - 5 % to AC 500 V + 10 %
Line frequency
f
line
50 Hz ... 60 Hz
Input current
I
N
1.52 A
(n
Motor
= 2000 rpm)
2.72 A
(n
Motor
= 2000 rpm)
3.2 A
(n
Motor
= 2000 rpm)
I
maxStart
2.45 A
3.15 A
3.7 A
PWM frequency
4/8 kHz
Interference immunity
EN 61800-3; 2nd environment (industrial environment)
Interference emission
EN 61800-3 category C3 (class A group 2 of EN 55011)
Climate class
EN 60721-3-3, class 3K3
Storage temperature
ϑ
L
−
25 °C to + 70 °C (EN 60721-3-3)
Proof of mechanical strength
according to EN 61800-5-1
Degree of protection
IP
Standard: IP 65 to EN 60529
(MOVIGEAR
®
housing closed and all cable glands sealed off. Possible
restrictions regarding application options)
With optional package for applications in wet areas: IP 66 to EN 60529
(MOVIGEAR
®
housing closed and all cable glands sealed off. Application
options not permitted for this drive package)
Duty cycle
S1, continuous (EN 60149-1-1 and 1-3)
Type of cooling
Self-cooling to DIN 41751 and EN 61800-5-1
Signaling functions
Display elements on housing to indicate the unit state
Installation altitude
h
Up to h
≤
1000 m without restrictions.
The following restrictions apply to heights
≥
1000:
•
From 1000 m to max. 4000 m:
–
I
N
reduction by 1% per 100 m
•
From 2000 m to max. 4000 m:
–
U
N
reduction by AC 6 V per 100 m
Over 2000 m only overvoltage class 2; external measures are required for
overvoltage class 3. Overvoltage classes according to DIN VDE 0110-1.
Required preventive measures
Ground the unit
MOVIGEAR
®
type
MGF..2
MGF..4
MGF..4/ET
Ambient temperature
I
N
reduction
Ambient temperature
ϑ
A
– 25 °C to + 60 °C
1)
3 % I
N
per K at 40 °C to 60 °C
1) Observe the permitted temperature range of the oil to be used (see chapter "Lubricant table").
P
i
f
kVA
Hz
n