6
Startup
Parameter description
Operating Instructions – CMP ELVCD
72
Parameter 888.0
CAN active after bus faults
The parameter defines whether CAN bus remains active after bus faults.
Parameter 889.0
CAN DSP305 active
This parameter indicates whether the automatic address assignment of the CAN bus
is active.
6.8.8
POS parameter
Parameter 907.0
Move to zero position after reference travel
The parameter defines whether the drive moves to the zero position after the refer-
ence travel.
Parameter 923.0
Lag error window (MultiMotion)
This parameter defines the tolerance by which the actual position may deviate from
the setpoint position without displaying a fault message.
Parameter 925.0
Response delay of lag error
This parameter defines how long the actual position may be outside the tolerance win-
dow before the "lag error" message is displayed.
22759468/EN – 11/2017