7
Operation
CMP ELVCD status list
Operating Instructions – CMP ELVCD
81
[13] "Axis-Connected" status display
Green: The drives communicate with the controller via the SBus. Initialization can take
several seconds after starting the controller.
Gray: No communication via the SBus takes place.
[14] "Inverter fault" status display
Red: There is a fault in the inverter. To display the fault code and other information,
move the mouse pointer over the fault display. An overview of the fault codes can be
found in section "Fault list" (→
85).
Gray: There is no fault.
[15] "IP address" display
Display of IP address of controller in MOVITOOLS
®
MotionStudio.
[16] [Back] button
Manual mode is exited using this button.
• The enable of the drive is canceled.
• The drives are braked with the rapid stop ramp.
• Actuation by the controller is enabled.
• The "Manual mode" window is closed.
[17] "Communication status" status display
Display of communication status between the controller and
MOVITOOLS
®
MotionStudio.
In order to execute diagnostic and control functions, the "Online" status must be
signaled. This is shown in the form of a continuous green bar.
If the "Offline" status is displayed, check the Ethernet connection and its settings.
7.5
CMP ELVCD status list
The MultiMotion program module shows the current status of the ELVCD drive. The
following table shows a descriptions of the status:
Code
Operating status
Meaning
0
NOT_READY_TO_
SWITCH_ON
The inverter performs a self-test. CAN communica-
tion not yet possible.
1
SWITCH_ON_
DISABLED
The controller has completed the self-test. CAN com-
munication is possible.
2
READY_TO_
SWITCH_ON
The inverter waits until the digital input DI09 "Con-
troller enable" is set to "1". (Controller enable logic
"Digital input and CAN").
3
SWITCHED_ON
You can switch on the inverter output stage.
4
OPERATION_
ENABLE
The motor is connected to the voltage supply. The
motor is controlled according to the selected operat-
ing mode.
5
QUICKSTOP_
ACTIVE
The Quick Stop Function is executed.
The motor is connected to the voltage supply. The
motor is controlled according to the Quick Stop func-
tion.
22759468/EN – 11/2017